00198152-02_OM_VirtualInkspotHandling_for_SSW7xx_EN.pdf - 第44页
Item - no. / Artikel - Nr.: 00198152 - 02 ASM Assembly Systems GmbH & Co. KG Rupert - Ma yer -Straß e 44 81379 München Deutschland www.asm -smt.com

Virtual Inkspot Handling for SSW 7xx / Operating Manual 10/2017 Edition
42
7 Troubleshooting
7.1 VIH with XML Files – Checking the Configuration
A feasibility check is performed for the configuration after machine booting (e.g., if WDTL is active
on the station only but not in SIPLACE Pro).
At the station the activation and configuration can be checked on the station console under
Configuration – Component …\Domains\Domains\Production\WhisperServer.
Figure 7-1: Checking configuration
Virtual Inkspot Handling for SSW 7xx / Operating Manual 10/2017 Edition
43
7.2 VIH with MES and BGK – No Valid Data
If the station sends a whisper request to the BGK or the preceding station and gets valid data, the
board is produced skipping the panels omitted by BGK.
If the station did not receive valid data the station stops and the board is displayed in yellow.
Possible errors may be:
– BGK is not available
– MES is not available
– MES has no data for the board
– MES data does not fit to the board
In case of an error the operator can perform one of the following actions:
– Provide BGK / MES / correct MES respectively and repeat the whisper request.
– Continue the board – the full board will then be produced.
– Abort the board and remove it from the station / line.

Item-no. / Artikel-Nr.: 00198152-02
ASM Assembly Systems GmbH & Co. KG
Rupert-Mayer-Straße 44
81379 München
Deutschland
www.asm-smt.com