HF Circuit .pdf - 第161页
2 - 111 LPDT-010301LD3 PCB du al convey or , track 2 conversi on boa rd „Transportati on cheek C “ (Sh . 6 of 8 ) LPDT-010301LD3_SH06 .DWG Stromlaufp lan/Circui t diagram SIPLACE H F Serie s 00365774-xx Lig ht b ar rie r…

2 - 110
LPDT-010301LD3 PCB dual conveyor, track 2
conversion board „Conveyor“ (Sh. 5 of 8)
X47ku
55
GND 6 GND 6
X43ku
+24V-
4
3
A1.21
1
2
+24V-
4
3
A1.22
1
2
X48ku
GND 6
5
GND 6
5
X44ku
2A1.23
+24V- 3
4
1
2A1.24
+24V- 3
4
1
4
SM_B+
5
6
SM_A-
SM_A+
3
2
X40ku
1
7
8
9
10
SM_B-
5
GND 6
X19ku
+24V-
A1.17
4
3
2
1
5
14GND
A2.36
A2.35
A2.34
Key
18
17
16
15
A2.20
A2.19
A2.18
A2.15
A2.17
A2.16
A2.26
12
13
11
10
7
9
8
6
SOKO/options
Placement sector 2
A2.25
+24V-
A2.24
X35ku
Key
4
3
2
1
5
14GND
A2.36
A2.35
A2.34
18
17
Key
16
15
A2.20
A2.19
A2.18
12
13
11
10
A2.15
A2.17
A2.16
A2.26
7
9
8
6
X37ku
A2.25
+24V-
A2.24
4
3
2
1
Key
X6ku ... X19ku, X29ku ... X33ku not used
5
6
4
3
X41ku
2
1
+24V-
GND
A1.43
Not used
GND 6
5
A1.44
+24V-
2
3
4
X45ku
1
X46ku
GND 6
5
GND 6
5
X42ku
2A1.19
+24V- 3
4
1
2A1.20
+24V- 3
4
1
LPDT-010301LD3_SH05.DWG
Stromlaufplan/Circuit diagram
SIPLACE HF Series
to plug X53ku
All connections from A2.xx
to plug X52ku
All connections from A1.xx
PLEASE NOTE:
All connections from SM_xx
to plug X51ku
PLEASE NOTE:
PCB dual conveyor, track 2
Not used Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Conversion board, "conveyor"
s
A&D EA
20.03.200320.03.03
22.09.05
22.09.05
03.
Key
Key
Key
Key
Key
Key
Key
Key
Key
(sheet 3)
(sheet 3)
(sheet 4)
Status
01.
01.
Doc. status
Modified
Function status
Product status
Date
Hi
Hi
Hi
Name Stand.
Check.
Date
Author Hi
CAD file:
Mat. no.:
Orig./Repl.f/Replaced by
LPDT-010301LD3
Sh.
Sh.8
5
(ku) 00359425-xx
Conversion board, "conveyor", track 2
4
6
8
7
5
3
2
X34ku
1
9
10
A2.23
A2.22
A2.21
Key
+24V-
11
12
13
14
15
16
17
18
GND
A2.9
A2.10
A2.11
A2.12
A2.13
A2.14
A2.31
A2.32
A2.33
Key
Placement sector 1
SOKO/options
A2.14 12
A2.33
18
17
Key
A2.32
A2.31
GND
16
15
14
13
A2.13
A2.12
A2.11
A2.10
11
10
8
9
A2.9
A2.23
+24V-
A2.22
5
6
7
4
3
Placement sector 1
A2.21
SOKO/options
X36ku
2
1
Key
Placement sector 2
SOKO/options
See page 5-32

2 - 111
LPDT-010301LD3 PCB dual conveyor, track 2
conversion board „Transportation cheek C“ (Sh. 6 of 8)
LPDT-010301LD3_SH06.DWG
Stromlaufplan/Circuit diagram
SIPLACE HF Series
00365774-xx
Light barrier
1
X12ky
wh
bn
6
5
3
4
Receiver module, placement sector 1
00365772-xx
Light barrier
Key
1
X11ky
4
1
Conversion board, "transportation cheek C"
PCB dual conveyor, track 2
Conversion board, "transportation cheek"
Not used
Not used
Not used
Not used
Not used
3
1
2
X9.1
W1W2
00370205-xx
00370206-xx
W2 W1
3
X10.1
2
1
3
2
1
X6.1
W1W2
s
A&D EA
20.03.200320.03.03
22.09.05
22.09.05
03.
Key
Key
Key
Key
Key
Key
Key
2
bn
bl
bk
bn
bl
bk
bn
bl
bk bk
bl
bn
bk
bl
bn
bk
bn
bl
Status
01.
01.
Doc. status
Modified
Function status
Product status
Date
Hi
Hi
Hi
Name Stand.
Check.
Date
Author Hi
CAD file:
Mat. no.:
Orig./Repl.f/Replaced by
LPDT-010301LD3
Sh.
Sh.8
6
Track 2
5
6
4
3
X1ky
2
1
MOT1-
MOT1+
MOT5-
MOT5+
MOT4-
MOT4+
MOT3-
MOT3+
MOT2-
MOT2+
MOT1-
MOT1+
(sheet 3)
"Conveyor", track 2
Conversion board
To plug X54ku
00365725-xx
(cable)
(ky) 00359424-xx
Side panel C
GND
EA0
EA2
EA4
EA6
EA8
EA1
EA3
EA5
EA7
EA9
+24V-
00359425-xx
22
31
34
33
32
29
30
28
27
24
26
25
23
3
17
6
5
3
4
Light barrier
00370203-xx
Key
Receiver, placement sector 1
X7ky
1
Key
bl
6
5
3
4
Light barrier
00370202-xx
Receiver, input conveyor
X6ky
1
bn
+24V-
bn
bn
bn
bn
GND
GND
EA1
+24V-
GND
EA2
+24V-
GND
EA3
+24V-
GND
EA4
+24V-
EA7
GND
+24V-
EA9
GND
+24V-
EA8
GND
+24V-
EA5
EA6
GND
+24V-
GND
+24V-
bn
2
5
6
4
3
Not used
1
2
X15ky
5
6
4
3
Not used
1
2
X14ky
Key
wh
6
5
4
3
gn
2
gn
2
Limit switch, width adjustment
00365765-xx
1
X13ky
wh
Key
bn
6
5
3
4
Receiver module, placement sector 2
21
20
19
18
15
16
14
13
8
10
12
11
9
7
6
5
4
X16ky
1
2
4
MOT2- 6
5
MOT2+
3
2
X2ky
1
4
MOT3- 6
5
MOT3+
3
2
X3ky
1
4
MOT4- 6
5
MOT4+
3
2
X4ky
1
4
MOT5- 6
5
MOT5+
3
2
X5ky
1
2
bk
bl
5
6
4
3
Light barrier
Key
bk
Receiver, output conveyor
X10ky
1
2
Key
bl
5
6
4
3
Light barrier
bk
Receiver, placement sector 2
X9ky
1
2
Key
bl
6
5
4
3
EA0 2
bk
2
bk
Light barrier
00370204-xx
Receiver, intermediate conveyor
X8ky
1
bl
See page 5-31

2 - 112
LPDT-010301LD3 PCB dual conveyor, track 2
conversion board „Transportation cheek D“ (Sh. 7 of 8)
24
26
25
23
3
17
21
20
19
18
15
16
14
13
8
10
12
11
9
7
6
5
4
X16kz
1
2
4
MOT2- 6
5
MOT2+
3
2
X2kz
1
4
MOT3- 6
5
MOT3+
3
2
X3kz
1
4
MOT4- 6
5
MOT4+
3
2
X4kz
1
4
MOT5- 6
5
MOT5+
3
2
X5kz
1
2
5
6
4
3
Key
Not used
X10kz
1
2
Light barrier
00370179-xx
Transmitter, placement sector 2
Key
bl
6
5
4
3
EA0 2
2
Light barrier
00370178-xx
Transmitter, intermediate conveyor
X8kz
1
6
5
3
4
Light barrier
00370177-xx
Key
Transmitter, placement sector 1
X7kz
1
Key
bl
6
5
3
4
Light barrier
00370176-xx
Transmitter, input conveyor
X6kz
1
bn
+24V-
bn
GND
GND
EA1
+24V-
GND
EA2
+24V-
GND
EA4
+24V-
EA7
GND
+24V-
EA9
GND
+24V-
EA8
GND
+24V-
EA5
EA6
GND
+24V-
GND
+24V-
bn
2
Key
5
6
4
3
1
2
X15kz
5
6
4
3
Key
1
2
X14kz
Key
wh
6
5
4
3
2
2
Limit switch, width adjustment
00365765-xx
1
X13kz
bl
Key
bn
6
5
3
4
Transmitter, output conveyor
00370180-xx
Light barrier
1
X12kz
6
5
3
4
Not used
Key
1
X11kz
LPDT-010301LD3_SH07.DWG
Stromlaufplan/Circuit diagram
SIPLACE HF Series
Conversion board, "transportation cheek D"
Status
01.
01.
Doc. status
Modified
Function status
Product status
Date
Hi
Hi
Hi
Name Stand.
Check.
Date
Author Hi
CAD file:
Mat. no.:
Orig./Repl.f/Replaced by
LPDT-010301LD3
Sh.
Sh.8
7
Conversion board, "transportation cheek"
5
6
4
3
X1kz
2
1
MOT1-
MOT1+
MOT5-
MOT5+
MOT4-
MOT4+
MOT3-
MOT3+
MOT2-
MOT2+
MOT1-
MOT1+
(sheet 3)
"Conveyor", track 2
Conversion board
To plug X55ku
00365726-xx
(cable)
(kz) 00359424-xx
Side panel D
GND
EA0
EA2
EA4
EA6
EA8
EA1
EA3
EA5
EA7
EA9
+24V-
00359425-xx
Input conveyor
00365719-xx
22
31
34
33
32
29
30
28
27
4
1
00365773-xx
Transmitter, placement sector 2
Light barrier
00365771-xx
Transmitter, placement sector 1
Light barrier
bn
wh
wh
bn
Cable, belt motor
PCB dual conveyor, track 2
Track 2
Key
bn
wh
M
Cable, belt motor
Output conveyor
Cable, belt motor
Placement sector 2
Cable, belt motor
Intermediate conveyor
Cable, belt motor
Placement sector 1
wh
Key
bn
Key
00365763-xx
wh
bn
00365762-xx
wh
Key
00365761-xx
bn
wh
bn
Key
00365720-xx
M
M
M
M
3
2
X12.1
1
W1W2
W2
2
X6.1
1
W1
W2
2
X1.1
1
W1
W1
2
1
W2
X5.1
4
GND 6
5
2
Key
EA3
+24V-
W2
2
3
1
W1
X9.1
1
X9kz
s
A&D EA
20.03.200320.03.03
22.09.05
22.09.05
03.
wh
bn
bn
bl
3
n.c.n.c.
bn
wh
bl
bnbn
bl
bl
bn bn
bl
n.c.n.c.
2
See page 5-31