HF Circuit .pdf - 第196页
4 - 9 0300321 7-030 201 TD3 C ompu ter unit S-COM 1 X2pn CAN bus1 X6pn CAN bus1 X7pn CAN bus2 X12pn CAN bus2 X11pn Reset Abort X9pu X5pu X8pu X7pu X6pu X3pu X4pu HS3 L VG A AUX Camera 1/3 Came ra 2/ 4 S-COM 2 S-COM 1 S-C…

4 - 8
03010005-050101TD1 Sub-distributor
DI12 -
DI7 -
DI6 -
40
28
27
B: Inspection label Identification: Test. engineer, month, year
A: Identification label
* Note
Apply the following labels on the assembly:
X15ra
X15ra
1
X17ra
X23ra
X24ra
X18ra
X21ra
X20ra
X19ra
X22ra
X74raX3raX4raX5raX6raX72ra X71raX73raX11raX12raX13raX14ra
A
B
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
X74raX3raX4raX5raX6raX72ra X71raX73raX11raX12raX13raX14ra
X17ra
X23ra
X24ra
X18ra
X21ra
X20ra
X19ra
X22ra
X1ra
PE
X10ra
X10ra
29
Reserved for vacuum pump option
Siemens AG
DI19 - S_HoodPCBinput
DI17 - S_Hood1
DI18 - S_COtable1
DI21 - S_Hood4
DI22 - S_COtable4
DI20 - S_EmergStopButtonPCBoutput
DO14 -
DO12 -
DO13 -
DO15 -
DI23 -
DI16 -
DI4 - S_D3ServoAddressBus
DI3 - S_D2ServoAddressBus
DI2 - S_D1ServoAddressBus
DI15 - S_EmergStopButtonMTC
DI8 - S_StartButton
DI9 - S_StopButton
DI13 - S_ControlOn
DI10 - S_RejectBin
DI11 - S_GantryCrash2
S_VacuumPumpOn
DI5 - S_PressureSensorMainValve
DI0 - EmergStopLoopOK
DI1 - S_D0ServoAddressBus
LEDs on the CAN I/O module
DO5 - Ctrl_ComprAirMainValve
DO4 - Ctrl_D4ServoSlot
DO3 - Ctrl_D3ServoSlot
DO2 - Ctrl_D2ServoSlot
DO1 - Ctrl_D1ServoSlot
DO0 - Ctrl_D0ServoSlot
DO6 -
DO10 -
DO11 -
DO8 -
DO9 -
DO7 -
DI14 -
X2rc
19 20 21 22 23 24 25 26
X3rc
X5rc
X4rc
X6rc
1817
45678910
161514
321 111213
8
4
765
321
X1rc
Vision DC distributor
A3 (rc)
X31ra
2
4
6
8
10
12
14
1
3
5
7
9
11
13
X30ra
A2
A1 (rb)
CAN I/O module
DO8
DO0
DO0
DO15
LEDs
LEDs
DI0
DI7
DI8
DI15
DI16
DI23
VCC
GND
EGND
EGND
DI4_5V
DI5_5V
DI6_5V
DI7_5V
12345678
X6rb
DI16
12345678
X5rb
1234567812345678
X4rb X3rb
DI17
DI18
DI19
DI20
DI21
DI22
DI23
DI8
DI9
DI10
DI11
DI12
DI13
DI14
DI15
DI0
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DO10
X7rbX8rb
12345678
P24
GND
X9rb
12345678
12345678
DO0
DO1
DO2
DO3
DO4
DO5
DO6
DO7
P24
P24
P24
GND
GND
GND
DO11
DO12
DO13
DO14
DO15
DO8
DO9
X2rb
X1rb
X10rb
S1
S1.8:
01
ON="1"
OFF="0"
S1.7:
S1.6:
S1.5:
S1.4:
S1.3:
S1.2:
S1.1: Baud rate
Platform
Location
Location
not used
1-Wire
not used
Terminating resistor
K1
S1
X3rd
X2rd
X1rd
X6rd
X7rd
X9rd
X5rdX4rd
X8rd
ON
87654321
A4 (rd)
Vision control 1 assy
8x
'AND gate
45678321
321
X1re
X3re
X2re
A5 (re)
Meaning
CAN-Error Switch
no CAN terminator
ON:OFF
CAN group = 0
CAN-Speed = 500 kbit/s
ID0
ID1
CAN-Error Switch
Boot
Reset OFF
Switch
S1.1
Setting
ID1
ID0
CAN-Speed = 1 Mbit/s
CAN group = 1
S1.2
S1.3
S1.4
S1.5
S1.6
S1.7
S1.8
CAN terminator 120 Ohm OFF
OFF
OFF
OFF
OFF
Switch S1 on the vision control unit
S1 switch on the CAN I/O module
ON
not used
not used
Main distributor
Sub-distributor
OFF
ON:
OFF: SIPLACE X series
SIPLACE HF, HF/3
OFF
OFF
OFF
OFF
not used
not used
not used
not used
not used
not used
I/O module
Slio emulation
1000k
500k
Terminating resistor
CAN
not used
not used
Location
Location
Platform
Baud rate
S1.8
S1.7
S1.5
S1.4
S1.3
S1.2
OFF:
ON:
OFF:
ON:
OFF:
ON:
OFF:
ON:
OFF:
ON:
OFF:
ON:
OFF:
ON:
SettingCodingMeaning
S1.1
Switch
ON
ON
S1.6 1-Wire ON:
OFF: 1-wire PC
1-wire MA ON
A1
1
1
Degree of accuracy
DIN 7167
Sub-distributor
03010005-050101TD1
08.08.2003
28.07.2005
Klein H.
FS04
FS03
FS02 K4, K5 no longer used
401023
400870 06.06.05
15.04.04
06.02.04 Tek
Tek
Tek
FS05 401960 28.07.05 Tek
A&D
16
Copying of this document, and giving it to others and the use
or communication of the contents thereof, are forbidden with-
out express authority. Offenders are liable to the payment of
damages. All rights are reserved in the event of the grant of
a patent or the registration of a utility model or design.
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwer-
tung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht
ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu
Schadenersatz. Alle Rechte für den Fall der Patenterteilung
oder GM-Eintragung vorbehalten.
12345678910111213141516
123456789101112131415
A
B
C
D
E
F
G
H
I
K
A
B
C
D
E
F
G
H
I
K
Format
Scale
Material
General tolerances
for nominal dimensions as per
ISO 2768 mH, unless
otherwise specified
Date Name
Author
Check.
Stand.
NameDateModified / ECO no.
SheetDrawing no. (FS RS DS DT L F)
Repl. f.
Sh.
SIPLACE HF series
ECR no.

4 - 9
03003217-030201TD3 Computer unit
S-COM 1
X2pn
CAN bus1
X6pn
CAN bus1
X7pn
CAN bus2
X12pn
CAN bus2
X11pn
Reset
Abort
X9pu X5pu X8pu
X7pu X6pu
X3pu X4pu
HS3LVGAAUX
Camera 1/3Camera 2/4
S-COM 2 S-COM 1
S-COM 1S-COM 2
Camera 2/4 Camera 1/3
AUX VGA HS3L
X4ptX3pt
X6ptX7pt
X8ptX5ptX9pt
Abort
Reset
3.3V + 52V
+ 5V
+12V
-12V
+15V
-15V
GND
CD
Floppy
Hard disk
L1
L2
H1
H2
LAN1 LAN2 HUB6 HUB5
HUB1HUB2HUB3HUB4
H3
H4
H5
H6
Activity
X14pcX13pc
X11pc
COM-ACOM-B
VGA
LAN
X6pc
X8pc X7pc
X5
L3
L4
L5
L6
KEYB.
USB
RUN
WD
L1
L2
USB
X14paX13pa
X11pa
USB
L2
L1
WD
RUN
USB
KEYB.
L6
L5
L4
L3
X5
X7paX8pa
X6pa
LAN
VGA
COM-B COM-A
Vision system (ICOS 1)
Communication assembly
Machine controller
Station computer
Dual LAN board with 6x hub
Battery
Hard disk/CD-ROM/Floppy
3.6V
Battery
A5
A6
A9
A11
A12
A13
A2
A1
A4
A3
A8
A7
A10
Sheet
B: Inspection label Identification: Test. engineer, month, year
A: Identification label
Apply the following labels on the outside (flush with the front plate):
A: Identification label with item number for the computer unit with MVS
* Note 2:
* Note 1:
Apply the following labels on the inside (flush with the front plate):
* Note 1
* Note2
DC/DC converter +3.3
Reserved f. coplanarity module
DC/DC converter +5V / +52V
DC/DC converter +/-12V +/-15V
Video multiplexer
Vision system (ICOS 2)
(Communication assembly)
Hard disk/CD-ROM/Floppy
ICOS 2ICOS 1GEMMC
X4pvX3pvX2pvX1pv
Hard disk
Floppy
CD
RS09
RS08
RS02 Tek
Tek
Tek23.02.04
15.12.03
19.02.03400411
400799
400923
23.02.04
11.06.2002 Rutz. B
Computer unit
03003217-030201TD3
1:2
A3
1
1
Degree of accuracy
DIN 7167
A&D
81234 765
F
E
D
C
A
B
F
E
D
C
A
B
1234 8765
Copying of this document, and giving it to others and the use
or communication of the contents thereof, are forbidden with-
out express authority. Offenders are liable to the payment of
damages. All rights are reserved in the event of the grant of
a patent or the registration of a utility model or design.
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwer-
tung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht
ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu
Schadenersatz. Alle Rechte für den Fall der Patenterteilung
oder GM-Eintragung vorbehalten.
Repl. f.
Dimens. variations
for nominal dimensions as per
ISO 2768 mH, unless
otherwise specified
Siemens AG
Modification / ECO no. Date Name
NameDate
Author
Check.
Stand.
Scale
Drawing no. (FS RS DS DT L F)
Format
Material
Sh.
Spare
SIPLACE HF series
ECR no.

4 - 10
03004917-010101TD3 Computer unit, base
1
1:2
11.06.2002 Rutz. B
11.06.02 TekneuUS01
03004917-010101TD3
11.06.02
A3
1
Copying of this document, and giving it to others and the use
or communication of the contents thereof, are forbidden with-
out express authority. Offenders are liable to the payment of
damages. All rights are reserved in the event of the grant of
a patent or the registration of a utility model or design.
Weitergabe sowie Vervielfaeltigung dieser Unterlage, Verwer-
tung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht
ausdruecklich zugestanden. Zuwiderhandlungen verpflichten zu
Schadenersatz. Alle Rechte fuer den Fall der Patenterteilung
oder GM-Eintragung vorbehalten.
FS ES US UA S F
A&D EA
ERDE
X62pz
X27pz
GND P24
X20 X26 X29 X28X21
GND
bn wh
X15pz
X3pz
X18pz
X1pz
X19pz X2pz
Computer unit, base
SIPLACE HF Series
Main no.
Sheet
Sh.
(Drawing number)
Format
NameDate
Scale
Author
Check.
Stand.
Date NameModifiedStatus
Retaining bar
Fan unit
Cable guide plate
Cover plate
Fan monitoring 2Fan monitoring 1
Fan
s