00198281-02_JG SmartFeeder 24-104 mm X_EN.pdf - 第35页
Splicing - Checking the Splicing Point 35 www.asm-smt.com 2.7 Checking the Splicing Point Identifying correct splicing. 1. If the tape is spliced correctly, the prongs of the rivet will be visible. 2. Top of a tape (8 mm…

Splicing - Splicing with the Multi-frame Tape Splice Gripper
34
www.asm-smt.com
1. Remove half of the protector strip.
Attention:
Do not touch the sticky surface!
2. Lay the adhesive strip on top of the com-
ponent tape and press firmly
3. Carefully remove the second half of the
protector strip.
4. Press down firmly on the adhesive strip.
Now open both interlocks of the multi-frame
tape splice gripper and remove the tape.

Splicing - Checking the Splicing Point
35
www.asm-smt.com
2.7 Checking the Splicing Point
Identifying correct splicing.
1. If the tape is spliced correctly, the prongs
of the rivet will be visible.
2. Top of a tape (8 mm)
3. Bottom of a tape (8 mm)
4. Top of a tape (24 mm)

Splicing - Checking the Splicing Point
36
www.asm-smt.com