ENA-X and ENA Series Vector Network Analyzers.pdf - 第18页
18 Measureme nt Applicat ion Softwar e Description 1 For E5080B ENA For E5081A ENA -X Additional I nformation Automatic fixture removal S96007B S96007B Time domain a nalysis S96010B S96010B Probe and fixtu re leakage cal…

18
Measurement Application Software
Description
1
For E5080B ENA
For E5081A ENA-X
Additional Information
Automatic fixture removal
S96007B
S96007B
Time domain analysis
S96010B
S96010B
Probe and fixture leakage
calibration
S96008B
S96008B
Enhanced time domain
analysis with TDR
S96011B
S96011B
Includes all capabilities of
S96010B.
Real-time S-parameter and
power measurement
uncertainty
S96015B
S96015B
Displays the measurement
uncertainty dynamically (real-time)
on the measurement trace.
Basic pulsed-RF
measurements lite for
E5080B
S96024B
N/A
Requires E5080B option 021/022.
Subset of S96025B.
Basic pulsed-RF
measurements for E5080B
S96025B
N/A
Requires E5080B option 021/022.
Basic pulsed-RF
measurements lite for
E5081A up to 20 GHz
N/A
S960240B
Subset of S960250B.
Basic pulsed-RF
measurements lite for
E5081A up to 44 GHz
N/A
S960241B
Subset of S960251B.
Basic pulsed-RF
measurements for E5081A
up to 20 GHz
N/A
S960250B
Basic pulsed-RF
measurements for E5081A
up to 44 GHz
N/A
S960251B
Add mechanical noise
tuner control for noise
figure/parameter
measurements
N/A
S96027B
Provides ability to control Maury
Microwave's LXI or Focus
Microwaves’ CCMT impedance
tuners.
Requires E5081A option
0K1/0K2/0N1/0N2 and application
software S96029B.
Noise figure measurements
with vector correction
2
S96029B
S96029B
Standard receivers are used on
E5080B. Option 0K1/0K2/0N1/0N2
are required to enable high gain
setting on E5081A.
IQ data bandwidth up to
1.5 GHz
N/A
S96050B
Requires either S960704/707B or
S960904/907B for E5081A.
E5080B is not supported.
IQ data bandwidth up to 4
GHz
N/A
S96051B
Requires either S960704/707B or
S960904/907B for E5081A.
E5080B is not supported.
Impedance analysis
S96041B
N/A
Provides impedance analysis of
small-sized Surface Mount Devices
(SMD) up to 10 GHz. Requires
16198A option 010 test fixture
3
and
85052DH02 mechanical cal kit.

19
Description
1
For E5080B ENA
For E5081A ENA-X
Additional Information
Modulation distortion up to
20 GHz
2
N/A
S960704B
Requires a supported vector signal
generator. Requires S96083B for
frequency converter
measurements.
Modulation distortion up to
44 GHz
2
N/A
S960707B
Requires a supported vector signal
generator. Requires S96083B for
frequency converter
measurements.
Scalar mixer/converter
measurements
2
S96082B
S96082B
Provides SMC measurement class.
Vector and scalar
mixer/converter
measurements
2
S96083B
S96083B
Provides SMC + phase
measurement class and vector
mixer characterization.
Embedded-LO capability
2
S96084B
S96084B
Gain-compression
measurements
S96086B
S96086B
Intermodulation distortion
measurements
2, 4
S96087B
S96087B
4-port VNA with the internal second
source (E5080B-4x2 or E5081A-
4xx) is recommended.
Source phase control
S96088B
S96088B
Requires the internal second
source (E5080B-4x2 or E5081A-
4xx).
Differential and I/Q device
measurements
2
S96089B
S96089B
Spectrum analysis for
E5080B
2
S96090B
N/A
Requires E5080B option 09x.
Spectrum analysis for
E5081A up to 20 GHz
2
N/A
S960904B
Spectrum analysis for
E5081A up to 44 GHz
2
N/A
S960907B
Active hot parameters,
restricted to 50 GHz
S96111B
S96111B
Requires the internal second
source (E5080B-4x2 or E5081A-
4xx).
True-mode stimulus
S96460B
S96460B
Requires the internal second source
(E5080B-4x2 or E5081A-4xx).
Multiport calibration
assistant
S96552B
S96552B
Provides a tool to flexibly define cal
sets of multiport measurements.
Requires one ECal module.
Vector network analyzer
(VNA) simulator – Standard
S94050B
S94050B
Runs on your PC and simulates
standard S-parameter
measurement class of Keysight’s
VNAs.
Vector network analyzer
(VNA) simulator -
Advanced
S94051B
S94051B
Runs on your PC and simulates
VNA functions including advanced
features of S96xxxB software
5
.
Device measurement
expert (DMX)
S94601B
S94601B
Assists the users in setting up
measurements automatically with
customizable templates.
Limit assistant
S94602B
S94602B
Allows to acquire the data from the
VNA, and easily generate limit
masks for production tests.