ENA-X and ENA Series Vector Network Analyzers.pdf - 第32页

32 Spectrum A nalysis (S96090B for E5080B, S960904B/S 960907B f or E5081A ) The Spectrum A nalyzer (SA) application add s high - performance mi crowave spectrum analy sis to the analyzer. With f ast stepped - FFT sweeps …

100%1 / 69
31
Source Phase Control (S96088B)
This application allows users to set calibrated, arbitrary phase differences between two internal sources
with the E5080B’s option 4x2 or E5081A’s 4-port options. The phase difference can be fixed or swept
between two specified phase values. S96088B also controls the relative power level between the sources
using the receiver-leveling feature. S96088B is targeted for active-load control, where the analyzer
provides a precise, electronically settable impedance to the output port of a device, while gain and output
power are measured. This capability can be combined with external load-pull software to create traditional
load-pull power contours. Not available with the E5080B option 2x0/4x0 or E5081A option 2xx with a
single internal source.
Differential and I/Q Device Measurements (S96089B)
In systems with a single source, the S96089B software can be used to characterize the harmonics of an
active device, such as an amplifier. The source is set to the fundamental frequency and the receivers can
easily be set to a multiple to measure the fundamental (x1), second (x2), third (x3), or higher harmonics.
Power sweeps can be used to characterize the harmonic levels versus power.
In systems with more than one source, the S96089B combines source-phase control of the internal or
external sources with frequency-offset mode, enabling simplified test of I/Q modulators/converters and
differential mixers, and harmonic measurements of differential amplifiers. The phase difference between
sources can be fixed (for example, at 90 or 180 degrees), or swept between two specified phase values.
Providing accurate control of the relative phase between sources eliminates the need for hybrid couplers
and baluns to create quadrature or differential signals. After achieving the desired phase alignment, the
instrument's receivers can be tuned to all frequencies needed to characterize the DUT. On an I/Q
modulator for example, measurements can be made of both the desired and suppressed conversion
bands, along with LO leakage, harmonics and other spurious signals. Phase sweeps can be used to
determine a DUT’s phase imbalance versus frequency.
In all cases, users can specify measurements with individual receivers or multiple receivers combined
with a wide range of mathematical operators. Power measurements can employ match correction for
increased accuracy.
32
Spectrum Analysis (S96090B for E5080B,
S960904B/S960907B for E5081A)
The Spectrum Analyzer (SA) application adds high-performance microwave spectrum analysis to the
analyzer. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application
provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements
can be done using test and reference receivers. This multi-channel SA can be used with the internal
swept-signal generators for efficient measurements of spurious signals emanating from mixers and
frequency converters. The SA application employs source-power and receiver-response calibration as
well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest
level of accuracy. Accurate and fast Noise Power Ratio (NPR) measurement capability is also included in
this software application. It provides the ability of setting up and controlling of external signal
generator/arbitrary waveform generators and performing the calibration of the flatness of a wideband
signal and distortion signals in notches and achieving very fast NPR measurements. Optional external
attenuators should be connected with the VNA’s test ports to avoid receiver compression when
measuring large signals.
This application also includes a VSA IQ data-link feature for sending IQ data from the VNA to Keysight’s
Pathwave 89600 VSA software for demodulation and analysis of EVM, AM-AM/AM-PM, and more. With
no additional license, the data link supports up to 200 MHz of modulation bandwidth with E5081A ENA-X
and a 29 MHz bandwidth with E5080B ENA. S95050B/51B software licenses extend the modulation
bandwidth to 1.5 GHz/4 GHz with ENA-X.
For use with E5080B ENA, S96090B software with E5080B option 09x spectrum analysis hardware is
required. There are two frequency choices intended for the E5081A ENA-X: S960904B to 20 GHz options
and S96097B to 44 GHz options.
Active Hot Parameters (S96111B)
Active hot parameters software allows the analyzer a more accurate method for testing Hot S-parameter,
gain and output power than traditional methods by utilizing the X-parameter technology.
It removes active device and system interaction to precisely calculate the active parameters and output
power into a nominal 50-ohm environment. The advanced theory removes system-to-system correlation
problems. S96111B also provides key parameters of optimal load for maximum power, maximum power
delivered to optimal load, and the DUT’s fundamental X-parameters. Total 14 traces (parameters) are
available with various sweep types, such as frequency sweep, power sweep, or two-dimensional
frequency and power sweep. Requires 4-port option configuration with the internal second source.
S96111B covers up to 50 GHz.
33
True-Mode Stimulus (S96460B)
The application provides mismatch-corrected true-mode (true differential mode and true common mode)
stimulus and enables accurate balanced measurements under real operating conditions. It also provides
balanced measurements with forward-only sweeps, reverse-only sweeps, and frequency or power
sweeps with arbitrary phase and amplitude offsets.
S96460B only works on E5080B’s option 4x2 or E5081A’s 4-port options with the internal second source.
Multiport Calibration Assistant (S96552B)
This application software provides a tool to flexibly create and manage cal sets for multiport
measurements. For example, two cal sets with independent test ports can be combined as one cal set
with a greater number of test ports. The software also offers a way to re-calibrate using a certain set of
test ports to refresh the cal set.
At least one ECal module is required for the operation of S96552B.
Material Measurements
The Keysight N1500A materials measurement suite streamlines the process of measuring complex
permittivity and permeability with a vector network analyzer. Various type of measurements, such as
transmission line and free space, arch reflectivity, resonant cavity, and coaxial probe are available as
options. The easy-to-use software guides the user through setup and measurement, instantly converting
S-parameter network analyzer data into the data format of your choice and displaying the results within
seconds. Results can be charted in a variety of formats: εr’, εr”, tand, μr’, μr”, tandμ, and Cole-Cole.
N1930xB Physical Layer Test System (PLTS) Software
The PLTS software platform has become an industry standard for calibration, measurement, and analysis
of linear passive interconnects such as cables, connectors, backplanes, and printed circuit boards. Utilizing
either a Vector Network Analyzer (VNA) or a Time Domain Reflectometer (TDR), fast and accurate
measurements can be obtained without in-depth knowledge of microwave measurement techniques. Refer
to www.keysight.com/find/plts or the technical overview (literature number 5989-6841EN) for more details.