ENA-X and ENA Series Vector Network Analyzers.pdf - 第20页

20 Description 1 For E5080B ENA For E5081A ENA -X Additional I nformation Automated meas urement expert (AMX) S94701A , S94702A , KS8400A S94701A, S94702A , KS8400A A smart software solut ion for automated multiport S - …

100%1 / 69
19
Description
1
For E5080B ENA
For E5081A ENA-X
Additional Information
Modulation distortion up to
20 GHz
2
N/A
S960704B
Requires a supported vector signal
generator. Requires S96083B for
frequency converter
measurements.
Modulation distortion up to
44 GHz
2
N/A
S960707B
Requires a supported vector signal
generator. Requires S96083B for
frequency converter
measurements.
Scalar mixer/converter
measurements
2
S96082B
S96082B
Provides SMC measurement class.
Vector and scalar
mixer/converter
measurements
2
S96083B
S96083B
Provides SMC + phase
measurement class and vector
mixer characterization.
Embedded-LO capability
2
S96084B
S96084B
Gain-compression
measurements
S96086B
S96086B
Intermodulation distortion
measurements
2, 4
S96087B
S96087B
4-port VNA with the internal second
source (E5080B-4x2 or E5081A-
4xx) is recommended.
Source phase control
S96088B
S96088B
Requires the internal second
source (E5080B-4x2 or E5081A-
4xx).
Differential and I/Q device
measurements
2
S96089B
S96089B
Spectrum analysis for
E5080B
2
S96090B
N/A
Requires E5080B option 09x.
Spectrum analysis for
E5081A up to 20 GHz
2
N/A
S960904B
Spectrum analysis for
E5081A up to 44 GHz
2
N/A
S960907B
Active hot parameters,
restricted to 50 GHz
S96111B
S96111B
Requires the internal second
source (E5080B-4x2 or E5081A-
4xx).
True-mode stimulus
S96460B
S96460B
Requires the internal second source
(E5080B-4x2 or E5081A-4xx).
Multiport calibration
assistant
S96552B
S96552B
Provides a tool to flexibly define cal
sets of multiport measurements.
Requires one ECal module.
Vector network analyzer
(VNA) simulator Standard
S94050B
S94050B
Runs on your PC and simulates
standard S-parameter
measurement class of Keysight’s
VNAs.
Vector network analyzer
(VNA) simulator -
Advanced
S94051B
S94051B
Runs on your PC and simulates
VNA functions including advanced
features of S96xxxB software
5
.
Device measurement
expert (DMX)
S94601B
S94601B
Assists the users in setting up
measurements automatically with
customizable templates.
Limit assistant
S94602B
S94602B
Allows to acquire the data from the
VNA, and easily generate limit
masks for production tests.
20
Description
1
For E5080B ENA
For E5081A ENA-X
Additional Information
Automated measurement
expert (AMX)
S94701A, S94702A,
KS8400A
S94701A, S94702A,
KS8400A
A smart software solution for
automated multiport S-parameter
measurements with the VNA and
E5092A
6
. Order each software model
and install in a PC or the analyzer.
DisplayPort DP cable
compliance test software
S94DPPCB
7,8
S94DPPCB
Performs automated compliance
tests of DisplayPort cable
assemblies using 4-port VNA.
USB Type-C interconnects
compliance test software
S94USBCB
7,8
N/A
9
Performs automated compliance
tests of USB Type-C interconnects
(e.g., cable assemblies,
connectors, or raw cables) using 4-
port E5080B.
Automotive cable test
software
AE6910L, AE2010L
N/A
Automotive Ethernet and SerDes
cable, connector, and harness
conformance. Automated VNA
setup and compliance
measurements with pass/fail
reporting using 4-port E5080B.
1. The S96xxxB software has six license types, please refer to “Keysight Software Licensing Options Provide Flexibility and
Support” for more detail.
2. Provides Frequency Offset Mode (FOM) to independently set the frequency of internal source(s) and receivers, and to configure
external sources using External Device Configuration.
3. The 16198A option 010 is connected with the E5080B’s options up to 20 GHz with either Type-N or 3.5-mm connectors. It offers
optional fixtures to mount 0402 mm (0402 mm / 01005 inch) and 0201 (0201 mm / 008005 inch) devices with option 200 and
100 respectively.
4. The most common method to use S96087B is to use a 4-port VNA with the internal dual source, with each built-in source
generating one tone. An external combiner (for example, hybrid power dividers 87302C, 87303C, or 87304C) is required to
combine the tones.
5. Features of S96007B and S96552B are not supported with the S94051B.
6. A 4-port ECal module (e.g., N4431D or N4433D) is recommended for multiport measurements.
7. Requires S96011B, KS8400B PathWave Test Automation, and KS8104B HTML5 Result Listener Plugin.
8. Supports L8990M-0LZ 20-port switch matrix to configure a multiport test system which eliminates the need for reconnections of
test cables with DUT.
9. E5081A ENA-X is not recommended for USB Type-C low-speed signal test which requires measurements from 300 kHz.
Automatic Fixture Removal (S96007B)
Many devices do not have coaxial connectors and are put in fixtures in order to measure them in a
coaxial environment. Accurately removing the effects of the fixture is required to get a good measurement
of the Device Under Test (DUT). This application adds a powerful application wizard to guide you through
characterizing a fixture and removing it from the measurement. Devices can be single-ended or
differential. Files can be saved in a variety of formats for later use in ENA, PNA, PXI VNA, Streamline
Series VNA, ADS, and PLTS.
Probe and Fixture Leakage Calibration (S95008B)
The software provides a process designed to address and correct crosstalk and leakage errors within the
measurement system. As measurement systems operate at high frequencies, the potential for crosstalk
increases, impacting the accuracy of measurements. With on-wafer measurement setups, probes and
components are placed very close to each other, resulting in crosstalk through physical coupling.
21
Additionally, modern DUTs often have more than two ports, leading to more complex crosstalk scenarios
within the measurement setup.
Addressing these challenges requires advanced calibration techniques and models that can accurately
account for and mitigate crosstalk, ensuring reliable and precise measurement results. The application
maintains the integrity of high-frequency testing and supports the development of next-generation
technologies.
Time Domain Analysis (S96010B)
This application enables the analyzer to view reflection and transmission responses in time or distance.
Use time domain to tune filters, gate out the response of fixtures and cables, characterize the impedance
of transmission lines and more.
Enhanced Time Domain Analysis with TDR (S96011B)
This application enables the analyzer to perform enhanced time domain analysis for high-speed data
applications. All functionalities of the S96010B are included (TDR/TDT mode). In addition, the S96011B
enables more detailed measurements and evaluations, such as eye-diagram/mask modes, without adding
PLTS software. Jitters and/or emphasis/equalization capabilities enables simulation of real-world signals and
environment. S96011B covers up to 53 GHz bandwidth with 8.42 ps rise time. Full calibration is available and
the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, mechanical
calibration kits or ECal with DC option (e.g., N443xD or N469xD with Option 0DC) are recommended.
Real Time S-Parameter and Power Measurement
Uncertainty (S96015B)
This application provides uncertainties for both S-parameter and power measurements on the analyzer.
The real-time display of the uncertainty associated with power and S-parameter traces increases the
confidence in the reproducibility of measurements. This allows users to implement pass/fail tests easily
because now the instrument quantifies the gray region that is in between a full pass or a full fail, apply
more realistic limit lines which can increase the production yield and reduce the defect percentage on the
finished products. This application easily establishes a metric to quantify the quality of the measurement
process, so your company’s quality control procedures are simplified. It includes the uncertainty
information for most Keysight calibration kits and provides national metrology institute traceability through
Keysight’s calibration kits. This application also helps you to include uncertainty information for your
product’s specifications and data sheets.