ENA-X and ENA Series Vector Network Analyzers.pdf - 第65页

65 CalPod C alibration R efresh M odules (8553xB/4xB) CalPod calibrat ion refresh modules allow in - situ calibration refresh es to be performed at the p ush of a button without removing the DUT or re - c onnecting calib…

100%1 / 69
64
U Band
U11644A standard, WR-19: 40 to 60 GHz. Includes:
11644-60006 U-band termination
11644-20004 U-band short
11644-20002 U-band shim
11644-60003 U-band 10 cm straight waveguide
11644-60018 U-band 5 cm straight waveguide
Verification Kits
All Keysight verification kits include:
Precision Z0 airline or match thru
Mismatched airline or mismatch thru
Fixed attenuators (except 85059V)
Traceable measured data and uncertainties
85051B 45 MHz to 18 GHz 7 mm kit
Includes attenuators, airline, and mismatch airline with data on a USB drive for use in confirming
calibrated system performance, traceable to national standards. Test procedure is provided in the service
manual.
85053B 300 kHz to 26.5 GHz 3.5 mm kit
Includes attenuators, airline, and mismatch airline with data on a USB drive for use in confirming
calibrated system performance, traceable to national standards. Test procedure is provided in the service
manual.
85055A 300 kHz to 18 GHz Type-N kit
Includes attenuators, airline, and mismatch airline with data on a USB drive for use in confirming
calibrated system performance, traceable to national standards. Test procedure is provided in the service
manual.
85057B 45 MHz to 50 GHz 2.4 mm kit
Includes attenuators, airline, and mismatch airline with data on a USB drive for use in confirming
calibrated system performance, traceable to national standards. Test procedure is provided in the service
manual.
85058V 45 MHz to 67 GHz 1.85 mm kit
Includes attenuators, airline, and mismatch airline with data on a USB drive for use in confirming
calibrated system performance, traceable to national standards. Test procedure is provided in the service
manual.
65
CalPod Calibration Refresh Modules (8553xB/4xB)
CalPod calibration refresh modules allow in-situ calibration refreshes to be performed at the push of a
button without removing the DUT or re-connecting calibration standards. CalPods are designed for any
measurement situation where it is desirable to ensure that a valid calibration is present before recording
measurement data. For example, they are useful for removing environmental effects such as cable
movement and thermal-based changes of cables, connectors, and adapters, as well as connector and
switch-matrix repeatability errors. The modules are especially useful in temperature, or thermal-vacuum
chamber testing. CalPod modules are equipped with 2.92 mm connectors.
85530B 20 GHz ambient-temperature CalPod
85531B 20 GHz temperature-compensated CalPod
85532B 20 GHz thermal-vacuum compatible CalPod
85540B 40 GHz ambient-temperature CalPod
85541B 40 GHz temperature-compensated CalPod
85542B 40 GHz thermal-vacuum compatible CalPod
85523B CalPod controller (provides control for up to 4 CalPods)
85556A CalPod drive-cable splitter (allows control for up to 12 CalPods)
85554A CalPod drive cable extension (10-meter cascadable extension cable)
66
E5081A, E5080B and E5071C Comparison
Switching from the E5071C to the E5081A or E5080B simplifies complex measurements with integrated
functionality and applications. You also get reliability and repeatability from best-in-class performance in
dynamic range, trace noise, speed, and frequency range.
Features
E5081A ENA-X
E5080B ENA
E5071C ENA
Frequency range
10 MHz to 20/44 GHz
(option 2x5, 2x6, 2N7, 4x5,
4x6, 4N7)
9 kHz to 4.5/6.5/9/14/18/20
GHz (option 2x0, 4x0, 4x2,
without bias tees)
100 kHz to 26.5/32/44/53
GHz (option 2x0, 4x0, 4x2,
without bias tees)
9 kHz to 4.5/6.5/8.5 GHz
(Option 2x0, 4x0, without
bias tees)
100 kHz to 4.5/6.5/8.5 GHz
(Option 2x5, 4x5, with bias
tees)
300 kHz to 14/20 GHz (with
bias tees)
Test port connectors
3.5 mm (m) (20 GHz)
2.4 mm (m) (44 GHz)
Type-N (f) (4.5/6.5/8.5 GHz)
3.5 mm (m) (14/20 GHz)
Type-N (f) (4.5/6.5/8.5 GHz)
3.5 mm (m) (14/20 GHz)
High stability
timebase
Optional (Option 1E5)
Optional (Option 1E5)
Optional (Option 1E5)
GPIB interface
Optional (Option 172)
Optional (Option 172)
Standard
Analog DC output
(DC sources)
Optional (Option 175)
Optional (Option 175)
No
Internal bias tees
No
Optional (Option 120, 140.
Up to 20 GHz)
Standard (Option 2x5, 4x5.
Up to 20 GHz)
Data storage
Removable SSD (standard)
Removable SSD (standard)
Built-in HDD (standard.
Option 019)
Removable HDD (Option
017)
Pulse modulator
hardware
Optional
Optional (Option 021/022)
No
Spectrum analysis
hardware
Optional
Optional (Option 09x)
No
Internal second
source
Optional (Option 4xx)
Optional (Option 4x2)
No
Configurable test set
Standard
No
No
Low noise receivers
for noise figure
measurements
Optional
No
No
Modulation distortion
analysis (EVM, ACP)
S960704B, S960707B
No
No
Frequency offset
mode / scalar
calibrated mixer
measurements
S96082B
S96082B
Option 008
Time domain analysis
S96010B
S96010B
Option 010
Enhanced time
domain analysis with
TDR
S96011B
S96011B
Option TDR