ENA-X and ENA Series Vector Network Analyzers.pdf - 第6页

6 Hardware Options Description For E5080B ENA For E5081A ENA -X Additional I nformation Add pulse mod ulator to internal 1st s ource E5080B - 021 1 N/A A dds the intern al pulse modul ators to the E5080B ’s first sour ce…

100%1 / 69
5
Spectrum Analysis Hardware Options (E5080B Only)
Choose one of spectrum analysis options for the E5080B (Option 09x). The frequency of Option 09x must
match with the operation frequency of the test set. S96090B application software is required for spectrum
analysis using the Option 09x.
Spectrum analysis on E5081A is enabled with S960904B or S960907B software. There is no required
spectrum analysis hardware option on the E5081A.
Option Number
Description
Additional Information
E5080B-090
Spectrum analysis hardware, 9 kHz to 4.5 GHz
E5080B-091
Spectrum analysis hardware, 9 kHz to 6.5 GHz
E5080B-092
Spectrum analysis hardware, 9 kHz to 9 GHz
E5080B-093
Spectrum analysis hardware, 9 kHz to 14 GHz
E5080B-094
1
Spectrum analysis hardware, 9 kHz to 20 GHz
E5080B-095
Spectrum analysis hardware, 100 kHz to 26.5 GHz
E5080B-096
Spectrum analysis hardware, 100 kHz to 32 GHz
E5080B-097
Spectrum analysis hardware, 100 kHz to 44 GHz
E5080B-098
Spectrum analysis hardware, 100 kHz to 53 GHz
1. Order Option 094 for 18 GHz options (opt.2H0/4H0/4H2). The maximum frequency of spectrum analysis is limited at 18 GHz.
Internal Bias Tees Options (E5080B Only)
Broadband internal bias tees are integrated for each test port. Order E5080B Option 120 for 2-port
options and order Option 140 for 4-port options
1
. DC power can be provided via BNC female connectors
on the rear panel of the analyzer for the operation of active components under test such as Tower
Mounted Amplifiers (TMAs). Internal bias tees up to 20 GHz are available on the E5080B.
Internal bias tees options are not available with E5081A ENA-X.
Option Number
Description
Additional Information
E5080B-120
Add internal bias tees for 2-port E5080B
Available with 4.5/6.5/9/14/20 GHz options only
E5080B-140
Add internal bias tees for 4-port E5080B
Available with 4.5/6.5/9/14/20 GHz options only
1. Internal bias tees options cannot be combined with 14 or 18 GHz options with Type-N connectors.
6
Hardware Options
Description
For E5080B ENA
For E5081A ENA-X
Additional Information
Add pulse modulator to
internal 1st source
E5080B-021
1
N/A
Adds the internal pulse modulators to the
E5080B’s first source.
Add pulse modulator to
internal 2nd source
E5080B-022
1
N/A
Adds the internal pulse modulators to the
E5080B’s second source.
Vector signal analysis
hardware
E5080B-190
2
N/A
Adds vector signal analysis capability to the
E5080B’s spectrum analysis hardware
(option 09x). The maximum bandwidth is
29 MHz.
Equipped with Type-N
connectors
E5080B-1NC
N/A
Adds Type-N connectors for 14 and 18 GHz
options (opt.2D0/4D0/4D2/2H0/4H0/4H2).
Cannot be combined with internal bias tees
options (opt.120 or 140).
Add noise receiver to port
1, 50 MHz to 20 GHz
N/A
E5081A-0K1
3
Adds the low-noise receiver to E5081A’s
port 1 to provide wideband noise figure and
noise-power measurements up to 20 GHz.
Add noise receiver to port
2, 50 MHz to 20 GHz
N/A
E5081A-0K2
3
Adds the low-noise receiver to E5081A’s
port 2 to provide wideband noise figure and
noise-power measurements up to 20 GHz.
Add noise receiver to port
1, 50 MHz to 44 GHz
N/A
E5081A-0N1
3
Adds the low-noise receiver to E5081A’s
port 1 to provide wideband noise figure and
noise-power measurements up to 44 GHz.
Add noise receiver to port
2, 50 MHz to 44 GHz
N/A
E5081A-0N2
3
Adds the low-noise receiver to E5081A’s
port 2 to provide wideband noise figure and
noise-power measurements up to 44 GHz.
Add high stability time
base
E5080B-1E5
E5081A-1E5
Improves specification of frequency
accuracy within ± 0.45 ppm.
Add GPIB interface
E5080B-172
E5081A-172
Add analog input and
output
E5080B-175
E5081A-175
Provides two DC sources and four input
ports for DC measurements.
1. S96024B or S96025B application software is required for pulsed-RF measurements.
2. E5080B’s spectrum analysis hardware (opt.09x), S96090B application software and PathWave Vector Signal Analysis (89600
VSA) software are required for vector signal analysis using the E5080B option 190.
3. S96029B application software is needed for all noise figure measurements.
7
Pulse modulation hardware (E5080B only. With Option 021, 022)
Option 021 adds internal pulse modulators to the E5080B’s first source. On the single source options, the
pulse modulation works for the port 1 and 2 (on Opt.2x0, 2-port options) and all four ports (on Opt.4x0, 4-port
options). On the second source options with Opt.4x2, Option 021 pulse modulation works only for port 1 and 2.
Option 022 adds internal pulse modulators to the E5080B’s second source. This option is available only
on the second source options (Opt. 4x2) and opt.022 pulse modulation works for port 3 and 4.
S96024B or S96025B software is required to enable the E5080B’s internal pulse modulators. Built-in
pulse modulators with the E5081A ENA-X are enabled with any of S960240B, S960241B, S960250B or
S96251B software and the hardware option is not required.
The internal pulse modulators can be controlled via the Application I/O D-sub connector on the rear panel
of the analyzer using an external pulse generator, or by using one of the internal pulse generators.
Vector signal analysis hardware (E5080B only. With Option 190)
Option 190 adds vector signal analysis capability to spectrum analysis hardware (Option 09x) with the
E5080B. The maximum bandwidth is 29 MHz.
S96090B spectrum analysis software for E5080B ENA and PathWave Vector Signal Analysis (89600
VSA) software are required to enable vector signal analysis using the E5080B Option 09x and 190.
Vector signal analysis functionality with the E5081A ENA-X is enabled with S960904B or S960907B
software and 89600 VSA software. Hardware options are not required.
Noise receiver hardware (E5081A only. With Option 0K1, 0K2, 0N1, 0N2)
This option adds a low-noise receiver to the ENA-X to provide wideband noise figure and noise-power
measurements on a broad range of devices. The noise receiver has three gain settings and contains the
necessary filters to eliminate out-of-band noise conversion. For E5081A 20 GHz options, Option 0K1
adds the noise receiver to the analyzer’s port 1, and Option 0K2 adds the noise receiver to the port 2. For
E5081A 44 GHz options, Option 0N1 adds the noise receiver to the port 1 and Option 0N2 adds the noise
receiver to the port 2.
The noise receiver start frequency is 10 MHz and it works up to the stop frequency of the instrument. The
noise receiver is intended for use with S96029B software. Without the software, the high gain setting for
noise figure measurements cannot be utilized.