4OM-1011-002.pdf - 第173页
0305-001 Tg0860-PM-MM *5 “COMP . LIBRARY INFO./FDR. OFFSET INFO” Displayed are the component library data and the feeder offset of the feeder No. set up in *1. *6 “RESUL T X (mm), Y (mm)” When the manual alignment operat…

0305-001 Tg0860-PM-MM
*2 “SELECT OPTION”
[FEEDER (B) OFFSET] Key
When the display (Fig. 4C232) is active and this key is
pressed, the display (Fig. 4C231) appears on the screen.
Use this function to perform the teaching operation on
the component center position.
[TEACH ECC. PICKUP POS [PICKUP LOC. ADJ]] Key
When the display (Fig. 4C231) is active and this key is
pressed, the display (Fig. 4C232) appears on the screen.
Use this function when a component has a groove, a
protrusion, etc., and cannot be picked up at the center
without any hindrance.
*3 “TEACH MENU”
“FEEDER (B) OFFSET (X, Y)” is modified additionally.
[CENTER 1-PT.] Key
When this key is pressed, the X/Y beam moves to the
center of the component.
“1POINT” and “2POINT”
These labels are used to align the component with two
diagonally-located points.
When the maximum outside dimensions of the compo-
nent exceeds “10 × 10 mm”, use these keys.
*4 “TEACH MENU”
[ALL BM. HD. ZERO] Key
This key is used to zero both Beams A and B.
When this key is selected and the [MOVE] button is
pressed, the zeroing operation starts.
[ECCENTRIC PT.] Key
When this key is selected and the [MOVE] button is
pressed, the P.E.C. recognition camera moves to the des-
ignated pick-up location correction position based on the
component center position (Position of “Design Position
+ Feeder (A) Offset + Feeder (B) Offset”) of the perti-
nent feeder, making it possible to capture the image.
Under this condition, shift to the trackball operation and
perform the manual alignment operation.
Note: It is necessary to correctly teach the component
center position before the eccentric position is
adjusted.
3-121
6.12 PICK-UP LOCATION (TRAY) Display (Option)
Fig. 4C234
Fig. 4C235
Fig. 4C236
CAUTION
“PICK-UP LOCATION ADJUST-
MENT X, Y” in the component li-
brary data is modified additionally.
Incorrect teaching operation will
cause the pick-up rate to deterio-
rate.

0305-001 Tg0860-PM-MM
*5 “COMP. LIBRARY INFO./FDR. OFFSET INFO”
Displayed are the component library data and the feeder
offset of the feeder No. set up in *1.
*6 “RESULT X (mm), Y (mm)”
When the manual alignment operation (using the trackball)
is completed, the results of the teaching operation are dis-
played.
Selection of [FEEDER (B) OFFSET] Key: FEEDER (B)
OFFSET
Selection of [TEACH ECC. PICKUP POS [PICKUP LOC.
ADJ]] Key: PICK-UP LOCATION ADJUSTMENT
*7 “TRAY MATRIX”
Shown are the coordinates (X, Y) which represent the pick-
up matrices of the selected tray.
*8 [TRAY MATRIX EDIT] Key
When this key is pressed, the display (Fig. 4C243) appears
on the screen.
Use this function to edit the pick-up matrices.
*9 “ALL BEAM ZERO”
When all beams are zeroed completely, the background turns
green. Otherwise, the background has no color.
*10 “RECOG. COMM.”
When “DISABLE” is set in the “P.E.C.” and “COMPO
NENT RECOGNITION” data boxes at the “TEST
MODE” display, the background color of “P.E.C. RECOG.”
and “COMP. RECOG.” becomes light red.
(No background color in normal cases)
Operation Procedure
Refer to “6.10 PICK-UP LOCATION (TAPE・VIB.
STICK) Display” for details.
3-122
6.12 PICK-UP LOCATION (TRAY) Display (Option)
Fig. 4C237
Fig. 4C238
Fig. 4C239
Fig. 4C240
Fig. 4C241
Fig. 4C242

0305-001 Tg0860-PM-MM
6.12.3 PICK-UP LOCATION TEACH - TRAY MATRIX EDIT
Display (Option)
• This display allows the editing of the pick-up matrices.
When the [TRAY MATRIX EDIT] key is pressed at the "FEEDER (B)
OFFSET・ECC. LOCATE OFFSET" display, the following display appears on
the screen.
*1 “PICK-UP MAT X, Y”
The pick-up matrices X and Y can be changed.
*2 [ ] Key
When this key is pressed, the “COMPONENT ID” field shifts horizontally
to the left, enabling you to view the first part of component IDs.
*3 [ ] Key
When this key is pressed, the “COMPONENT ID” field shifts horizontally
to the right, enabling you to view the comments.
Operation Procedure
(1) Select the key under “X” or “Y”.
(2) Specify the matrix position, using the ten-key pad.
(3) Press the [SET] key.
3-123
6.12 PICK-UP LOCATION (TRAY) Display (Option)
*1
*2
*3
Fig. 4C243