User manual SIPLACE D4 5 Tasks for the operating personnel From software version SR.605.xx 07/2008 EN Edition 5.2 Controls and displays 197 5.2 Controls and displays 5.2.1 Position 5 Fig. 5.2 - 1 Controls and displays (1…

5 Tasks for the operating personnel User manual SIPLACE D4
5.1 Personnel profile From software version SR.605.xx 07/2008 EN Edition
196
5.1.3.2 Tasks
The service personnel's duties include:
– Major preventive maintenance jobs
– Mounting replacement parts
– Editing machine data
– Calibrating the machine
5.1.4 Operator level "Programmer"
5.1.4.1 Training courses
A list of training courses can be found in Section 1.3, page 22.
5.1.4.2 Tasks
The programmer's jobs are as follows:
– Preparing CAD files
– Creating and calibrating vision data (teaching)
– Writing placement programs
– Implementing a new job
– Data maintenance
– Data backup

User manual SIPLACE D4 5 Tasks for the operating personnel
From software version SR.605.xx 07/2008 EN Edition 5.2 Controls and displays
197
5.2 Controls and displays
5.2.1 Position
5
Fig. 5.2 - 1 Controls and displays
(1) Operator panel on the power supply side (7) LCD touchscreen
(2) Main power switch (8) EMERGENCY STOP button
(3) Stop button (black) (9) Indicator lamps
(4) Start button (white) (10) Button for raising the CO table
(beneath the cover flap)
(5) Component counter
(6) Keyboard

5 Tasks for the operating personnel User manual SIPLACE D4
5.2 Controls and displays From software version SR.605.xx 07/2008 EN Edition
198
5.2.2 Description
All the controls can be reached by a 1.40 m tall person.
Main power switch 5
The main power switch is used to switch the power supply to the machine on and off.
WARNING
Some parts inside the machine carry potentially lethal voltages - even when switched off at the
main power switch. 5
Stop button 5
This button is used to stop the machine.
Start button 5
This button starts the machine after it has been switched on or after faults have been eliminated.
EMERGENCY STOP button 5
The EMERGENCY STOP button latches in the ON position when pressed. The power supply to
the gantry axes, the component trolleys, conveyors and used tape cutters is interrupted and the
voltage supplied to the star axes of the placement heads is reduced. Turn the button to release it.
Component counter 5
The component counter displays the number of components processed in increments of ten.
LCD touchscreen 5
There is a flat screen on either side of the machine.
Keyboard 5
The keyboard is located beneath the monitor.
Indicator lamps 5
The sequence of colors of the indicator lamps is white - green. These lamps are used to signal