00195779-0102_UM_D4_SR605_EN.pdf - 第88页

3 Technical data for the machine User manual SIPLACE D4 3.2 Ratings From software version SR.605.xx 07/2008 EN Edition 88 3.2 Ratings 3.2.1 Electrical ratings 3 Feeding capacity 48 tape feeder modules 3 x 8 mm S (144 tra…

100%1 / 266
User manual SIPLACE D4 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.1 Performance data
87
3 Technical data for the machine
3.1 Performance data
3
Types of placement
head
12-segment Collect&Place head (C&P12)
PLEASE NOTE IPC value [comp./h]
According to the vendor-neutral conditions of the IPC 9850 standard
published by the Association of Connecting Electronics Industries.
SIPLACE Benchmark value [comp./h]
The SIPLACE benchmark value is measured during the machine
acceptance tests. It corresponds to the conditions set out in the
SIPLACE scope of service and supply.
Theoretical maximum output value [comp./h]
The theoretical maximum output value is calculated from the most
favorable conditions for each machine type and setting, and corre-
sponds to the theoretical conditions normally used in the industry.
Number of gantries
4
IPC value Benchmark value Theoretical value
Placement head con-
figuration and place-
ment head rate
[comp./h]
4 x C&P12 57,000 66,000 81,500
Range of components 0.4 x 0.2 mm² (01005)
a
; 0.6 x 0.3 mm (0201)
b
to 18.7 x 18.7 mm²
Component height 6 mm
Placement accuracy CO camera type 28 (18x18): ± 50 μm (3σ), ± 67 μm (4σ)
CO camera type 29 (27x27): ± 50 μm (3σ), ± 67 μm (4σ)
CO camera type 38 (16x16): ± 50 μm (3σ), ± 67 μm (4σ)
Angular accuracy CO camera type 28 (18x18): ± 0.53° (3σ), ± 0.71° (4σ)
CO camera type 29 (27x27): ± 0.53° (3σ), ± 0.71° (4σ)
CO camera type 38 (16x16): ± 0.53° (3σ), ± 0.71° (4σ)
Component feeding 4 component trolleys with tape reel container and integral waste
container (12 x 30 mm wide locations per component trolley )
Feeder module types Tapes, bulk cases, stick magazines, application-specific OEM feeder
modules, surftape feeder modules (8, 12, 16 mm)
3 Technical data for the machine User manual SIPLACE D4
3.2 Ratings From software version SR.605.xx 07/2008 EN Edition
88
3.2 Ratings
3.2.1 Electrical ratings
3
Feeding capacity 48 tape feeder modules 3 x 8 mm S (144 tracks)
48 tape feeder modules 2 x 8 mm S (96 tracks)
48 tape feeder modules 12/16 mm S (48 tracks)
32 tape feeder modules 24/32 mm S (32 tracks)
PCB format
(LxW)
Single conveyor
50 x 50 mm² to 368 x 460 mm²
50 x 110 mm² to 610 x 460 mm² (Long board option)
Width up to 508 mm for Wide board configuration
Dual conveyor
50 x 50 mm² to 368 x 216 mm²
50 x 120 mm² to 610 x 216 mm² (Long board option)
Width up to 242 mm for Wide board configuration
Dual conveyor in Single conveyor mode
50 x 50 mm² to 368 x 380 mm²
50 x 120 mm² to 610 x 380 mm² (Long board option)
PCB thickness 0.3 to 4.5 mm (thicker PCBs available on request)
a) With 01005 package
b) With 0201 package
Supply voltage 3 x 200 VAC ± 5%; 50/60 Hz (Japanese version)
3 x 208 VAC ± 5%; 50/60 Hz (U.S.A. version)
3 x 230 VAC ± 5 %; 50/60 Hz
3 x 380 VAC ± 5 %; 50/60 Hz
3 x 400 VAC ± 5%; 50/60 Hz (European version)
3 x 415 VAC ± 5 %; 50/60 Hz
Fuse 3 x 32 A (3 x 200 VAC / 3 x 208 VAC / 3 x 230 VAC)
3 x 16 A (3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Nominal apparent power 3.3 kVA
Rated current consumption 8.2 A / 3 x 400 VAC
User manual SIPLACE D4 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.2 Ratings
89
3.2.2 Compressed air supply
3
3.2.3 Compressed air specification
3
3.2.4 Ambient conditions
3
3.2.5 Ambient conditions for the packaging, transportation and storage
3
Compressed air pressure
p
min
p
max
0.55 MPa = 5.5 bar
1.0 MPa = 10 bar
Compressed air connection R 3/4" internal thread (pipe thread) with 1/2" hose
connector
Compressed air consumption with
a
4 tape
cutters and 4 placement heads
a) Under normal atmospheric conditions at 20°C and 1013 hPa
950 Nl/min
400 Nl/min with vacuum pump (see Section 6.12
,
page 245
)
Operating pressure 0.48 MPa (4.8 bar)
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint + 3°C
Temperature range Between 15°C and 35°C
Relative atmospheric humidity Between 30% and 90% at 20°C
Ambient pressure > 750 mbar (corresponds to 2,500 m above mean sea level)
Temperature range Between -25°C and 55°C
Relative atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization