00195779-0102_UM_D4_SR605_EN.pdf - 第210页

5 Tasks for the operating personnel User manual SIPLACE D4 5.6 Setting up the feeder modules From software version SR.605.xx 07/2008 EN Edition 210 5.6.1 Prep aring the component table and S feeder modules for set-up → C…

100%1 / 266
User manual SIPLACE D4 5 Tasks for the operating personnel
From software version SR.605.xx 07/2008 EN Edition 5.6 Setting up the feeder modules
209
5.6 Setting up the feeder modules
5
Fig. 5.6 - 1 Component table with 12 locations for S feeder modules
(1) S feeder module
(2) Centering pin
(3) Centering ball
(4) Component table
(5) Connecting cable for the S feeder module
5 Tasks for the operating personnel User manual SIPLACE D4
5.6 Setting up the feeder modules From software version SR.605.xx 07/2008 EN Edition
210
5.6.1 Preparing the component table and S feeder modules
for set-up
Clean the contact surface for the feeder module.
Clean the contact surface on the component table.
Remove loose components from the component table with a brush or use a vacuum cleaner
with appropriate nozzle.
Remove any firmly attached components with the screwdriver.
CAUTION 5
Avoid removing components from the component table with your fingers. You may hurt your-
self with tiny splinters of metal.
5.6.2 Inserting S feeder modules
First place the front of the feeder module (item 1 in Fig. 5.6 - 1, page 209), i.e. the side with
the slotted foot, onto the component table (item 4 in Fig. 5.6 - 1
, page 209), so that the cen-
tering pin (item 2 in Fig. 5.6 - 1
, page 209) on the component table slides into the slot in the
feeder module foot.
Then lower the back of the feeder module until the centering ball (item 3 in Fig. 5.6 - 1
, page
209
) disappears completely into the hole in the feeder module.
Make sure that the feeder modules are placed correctly on the component table to suit their
width (see Fig. 5.6 - 2
, page 211).
Check that the feeder module is firmly seated on the component table by tapping the side of
the feeder module with your finger. You should not be able to move it.
Connect the feeder module plug (item 5 in Fig. 5.6 - 1
, page 209) to the socket beneath the
location. The red dot on the plug must point towards the red dot on the socket.
PLEASE NOTE 5
When you connect the feeder module, make sure that you use the right socket for the location
since the feeder module receives the control pulse via this socket. The feeder module may
not work correctly if it is not connected to the right socket. The user manual for the feeder
modules used will contain detailed information on the assignment of plugs to sockets.
User manual SIPLACE D4 5 Tasks for the operating personnel
From software version SR.605.xx 07/2008 EN Edition 5.6 Setting up the feeder modules
211
Fig. 5.6 - 2 Inserting 30 or 45 mm wide S feeder modules on the component table
(1) Feeder module, 30 mm wide
(2) Feeder module, 45 mm wide
(3) Centering ball
(4) Component table