00195779-0102_UM_D4_SR605_EN.pdf - 第59页
User manual SIPLACE D4 2 Operational safety From software version SR.605.xx 07/2008 EN Edition 2.6 Safety equipment 59 The travelin g range of the gantries has four pr ot ective covers that can be swung upwar ds. There a…

2 Operational safety User manual SIPLACE D4
2.6 Safety equipment From software version SR.605.xx 07/2008 EN Edition
58
2.6 Safety equipment
2.6.1 Protective covers
2
Fig. 2.6 - 1 Protective covers
(1) Protective covers
(2) Safety panels
(3) Cover flap on the input belt
(4) Hand guard on the input belt
(5) Cover flap on the output belt
(6) Hand guard on the output belt

User manual SIPLACE D4 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.6 Safety equipment
59
The traveling range of the gantries has four protective covers that can be swung upwards. There
are side screens to prevent access to the inside of the machine from the side. Access to the PCB
conveyor is protected by covers, which can be pivoted upwards, over the input and output belts
and guards on both belts.
Function 2
The main power supply to the gantry axes is interrupted immediately if one of the protective covers
is swiveled up or one of the cover flaps on the PCB conveyor is raised. The gantry axes stop mov-
ing. The message "Close cover" is displayed on the screen.
→ Close the protective covers and press one of the start buttons to continue placement.
2
Fig. 2.6 - 2 Position of the start button (white) on the machine
(1) Start button (white) on the machine

2 Operational safety User manual SIPLACE D4
2.6 Safety equipment From software version SR.605.xx 07/2008 EN Edition
60
2.6.2 Switches and buttons on the machine
2.6.2.1 Position of switches and buttons on the machine
2
Fig. 2.6 - 3 Position of switches and buttons - View of the PCB output side
(1) Main power switch
(2) Stop button (black) on the operator panel on the power supply side
(3) Start button (white) on the operator panel on the power supply side
(4) Component counter on the operator panel on the power supply side
(5) EMERGENCY STOP button on the output side
(6) Start button (white) on the output side
(7) Stop button (white) on the output side
(T) PCB transport direction