OPERATING MANAUAL(FOR ENGINEERS).pdf - 第125页
Page 5-29 TEACHING 5 T eaching the Mount Position 12 . When editing is needed, after checking SEQ No., press red triangle, around the recognition screen holding UNLOCK to move the center of pattern to the center of scree…

Page 5-28
Teaching the Mount Position
9. Press
UNLOCK
and Teach start .
• The board is carried in to X-Y table, and moves
to the position to be previously mounted.
10. Adjust the lamp value to that easy to
see the screen.
11. When SEQ No. is known,
press
UNLOCK
and Set SEQ to enter
that numerals ( No. ).
• Move the board to the mounting position of
selected SEQ No.
∗ When SEQ No. is not known,
press
UNLOCK
and Complete to move the board
to the next coordinates having mount position
deviation.
NOTICE
Do not touch the recognition
camera here.
Pressing small red triangle, on
the recognition screen, holding
UNLOCK
moves the coordinates,
and then pressing
UNLOCK
and
Complete renews the mount data.
3Y3C-E-EMD05-A01-01
1
2
To the next page

Page 5-29
TEACHING
5
Teaching the Mount Position
12. When editing is needed,
after checking SEQ No., press red
triangle, around the recognition
screen holding
UNLOCK
to move the
center of pattern to the center of
screen.
13. Press
UNLOCK
and Complete .
• Mount coordinates are renewed.
14. Press and return to the
screen for procedure 6.
15. Press Mount data edit on the screen
for procedure 6 again, and check that
the coordinates are renewed, then
press .
16. Press again.
17. Press Yes .
• Board is carried out and teaching is finished.
• Production data teaching screen appears.
3Y3C-E-EMD05-A01-02
4G3C-EEn-DmPtMp-001
3Y3C-EEn-DmMd-002

Page 5-30
3Y3C-E-EMD05-A01-00