OPERATING MANAUAL(FOR ENGINEERS).pdf - 第93页

Page 4-15 DA T A MODIFICA TION 4 4-7 Mount Data Mount data is checked and corrected. 1 . Press Mount data . • Mount data screen appears. 2 . X and Y coordinates and mounting angle are corrected. • Mounting points : All p…

100%1 / 168
Page 4-14
4-6 Block Attribute Data
Block attribute data is checked and corrected.
1. Press Block attribute data .
Block attribute data screen appears.
2. Correct bad block mark coordinates
(BAD. X, BAD. Y) if necessary.
[Items]
• BL : Block No.
• BAD : Bad block
• ORG. X and Y : Block origin coordinate
• BAD. X and Y : Bad block mark coordinate
• ROT : No. of block extension angle
• Press Call by BL and enter the block No. to
move cursor to the specified block No.
3Y3C-E-EMD04-A01-00
1 : right 90° 2 : 180°
3 : left 90°
0 : 0°
Page 4-15
DATA MODIFICATION
4
4-7 Mount Data
Mount data is checked and corrected.
1. Press Mount data .
• Mount data screen appears.
2. X and Y coordinates and mounting
angle are corrected.
Mounting points : All points including skip
Skip points : Points to skip mounting
Skip
BAD : Bad block
USKP : Feeder layout skip
BSKP : Block data skip
MSKP : Mount data skip
In setting the skip by some data, screen
displays data in the order of priority above.
Skip ........ Skip (MSKP) is set.
Call by SEQ ........ Cursor moves to the specified SEQ No.
Call by coord ........ Cursor moves to SEQ of the set X and Y coordinates lower than the
current cursor position.
Call by cmnt ........ Cursor moves to SEQ including the set comment lower than the current
cursor position.
3Y3C-E-EMD04-A01-01
Page 4-16
3Y3C-E-EMD04-A01-00
4-8 Function Switch
The setting of function switch to set the condition of driving is checked and corrected.
1. Press Function switch .
The function switch screen appears.
Only the pass mode, ON and OFF can be
changed.
Other conditions are only checked and set on
PT100 side.
Pass mode..................................Board is transferred to the post-process not mounted.
Board recognition......................Board is recognized.
Bad board mark inspection ......Bad board mark is recognized.
Bad block mark inspection .......Bad block mark is recognized.