3 Graphical user int erface SIPLACE Software Guide SR.503.xx 3.3 User interf ace - views and menus Issue 12/01 E N 42 Click the M achine option s... menu i tem ( or the app ropriat e button in the wor king area o f the…

SIPLACE Software Guide SR.503.xx 3 Graphical user interface
Issue 12/01 EN 3.3 User interface - views and menus
41
Click the checkboxes corresponding to the machine options which you want to activate or de-
activate.
When the machine is switched off, all options are reset except those listed below:
– Comp. verification with barcode
– Feeder position recognition
– PCB data transfer from PA1(„Whispering Down the line“)
NOTE
At "Operator" access level, it is only possible to activate and deactivate the conveyor interface op-
tions. 3
If you want to activate or deactivate the options for a processing area or view its configuration,
click the Processing area 1 or Processing area 2 tab to select the required area.
The display switches to the selected processing area (see example below for PA1).
3
Fig. 3.3 - 5 „Machine options - Processing area 1" dialog box (Example: HS50)
Activate/deactivate the checkboxes corresponding to the required machine options.
Click Accept to save the settings.
Machine options... (S25-HM) 3
Depending on access level, you can obtain information about the station configuration ("Opera-
tor") or activate or deactivate the displayed machine options ("Line engineer", "Service"). 3

3 Graphical user interface SIPLACE Software Guide SR.503.xx
3.3 User interface - views and menus Issue 12/01 EN
42
Click the Machine options... menu item (or the appropriate button in the working area of the
main view). The following window is displayed.
3
Fig. 3.3 - 6 „Machine options - entire machine“ (Example: S25-HM) dialog box
NOTE
Only those machine options are displayed which are configured at the current station. 3
Click the checkboxes corresponding to the machine options which you want to activate or de-
activate.
When the machine is switched off, all options are reset except those listed below:
– Comp. verification with barcode
– Feeder position recognition
– MTC: Component pick-up strategy FiFo
NOTE
At "Operator" access level, it is only possible to activate and deactivate the conveyor interface op-
tions. 3

SIPLACE Software Guide SR.503.xx 3 Graphical user interface
Issue 12/01 EN 3.3 User interface - views and menus
43
Access level... 3
It is possible to protect some of the functions of the user interface against unauthorized use by
setting an access level and allocating a password. Functions which are not accessible from a
given access level cannot be executed since the associated push buttons, radio buttons and
menu commands are either inactive or not displayed. 3
You can choose between the access levels "Operator", "Line engineer" and "Service". Passwords
can be allocated for the access levels "Line engineer" and "Service". 3
Click the Access level... menu item.
The „Access level“ dialog box is displayed.
3
Fig. 3.3 - 7 "Access level" dialog box
Click the radio button for the required access level.
Click the "Change password" button to the right of the access level if you want to allocate a
password or change an existing password.