00193325-01.pdf - 第42页

3 Graphical user int erface SIPLACE Software Guide SR.503.xx 3.3 User interf ace - views and menus Issue 12/01 E N 42  Click the M achine option s... menu i tem ( or the app ropriat e button in the wor king area o f the…

100%1 / 124
SIPLACE Software Guide SR.503.xx 3 Graphical user interface
Issue 12/01 EN 3.3 User interface - views and menus
41
Click the checkboxes corresponding to the machine options which you want to activate or de-
activate.
When the machine is switched off, all options are reset except those listed below:
Comp. verification with barcode
Feeder position recognition
PCB data transfer from PA1(„Whispering Down the line“)
NOTE
At "Operator" access level, it is only possible to activate and deactivate the conveyor interface op-
tions. 3
If you want to activate or deactivate the options for a processing area or view its configuration,
click the Processing area 1 or Processing area 2 tab to select the required area.
The display switches to the selected processing area (see example below for PA1).
3
Fig. 3.3 - 5 „Machine options - Processing area 1" dialog box (Example: HS50)
Activate/deactivate the checkboxes corresponding to the required machine options.
Click Accept to save the settings.
Machine options... (S25-HM) 3
Depending on access level, you can obtain information about the station configuration ("Opera-
tor") or activate or deactivate the displayed machine options ("Line engineer", "Service"). 3
3 Graphical user interface SIPLACE Software Guide SR.503.xx
3.3 User interface - views and menus Issue 12/01 EN
42
Click the Machine options... menu item (or the appropriate button in the working area of the
main view). The following window is displayed.
3
Fig. 3.3 - 6 „Machine options - entire machine“ (Example: S25-HM) dialog box
NOTE
Only those machine options are displayed which are configured at the current station. 3
Click the checkboxes corresponding to the machine options which you want to activate or de-
activate.
When the machine is switched off, all options are reset except those listed below:
Comp. verification with barcode
Feeder position recognition
MTC: Component pick-up strategy FiFo
NOTE
At "Operator" access level, it is only possible to activate and deactivate the conveyor interface op-
tions. 3
SIPLACE Software Guide SR.503.xx 3 Graphical user interface
Issue 12/01 EN 3.3 User interface - views and menus
43
Access level... 3
It is possible to protect some of the functions of the user interface against unauthorized use by
setting an access level and allocating a password. Functions which are not accessible from a
given access level cannot be executed since the associated push buttons, radio buttons and
menu commands are either inactive or not displayed. 3
You can choose between the access levels "Operator", "Line engineer" and "Service". Passwords
can be allocated for the access levels "Line engineer" and "Service". 3
Click the Access level... menu item.
The „Access level“ dialog box is displayed.
3
Fig. 3.3 - 7 "Access level" dialog box
Click the radio button for the required access level.
Click the "Change password" button to the right of the access level if you want to allocate a
password or change an existing password.
The dialog box for password entry is now displayed.