00193325-01.pdf - 第98页
SIPLACE Softw are Guide SR.503.xx 7.5 Option „GE M Interface“ Issue 12/01 EN 98

SIPLACE Software Guide SR.503.xx
Issue 12/01 EN 7.5 Option „GEM Interface“
97
7.5 Option „GEM Interface“
7.5.1 Purpose
The GEM Interface makes it possible to operate a SIPLACE station with any GEM-compatible
host computer. The station computer of the SIPLACE station must still be connected to a line com-
puter in order to ensure that the machine, set-up and cluster data can all be programmed and
downloaded to the station computer. The GEM Interface serves to record the operating data of the
machine during placement operation. 7
7.5.2 Description
NOTE:
Please refer to the GEM Interface Option User Manual and the Online Help for a detailed
description of this option. 7
7
SIPLACE Software Guide SR.503.xx
7.5 Option „GEM Interface“ Issue 12/01 EN
98
SIPLACE Software Guide SR.503.xx
Issue 12/01 EN 7.6 "Traceability" Option
99
7.6 "Traceability" Option
Please refer to the Traceability User Manual for complete documentation of the
Traceability option. 7
7.6.1 Introduction
In printed circuit board production, Traceability means the tracing back of production over a long
period of time. For example, traceability allows you to determine which components out of what
batches have been used for the in-line assembly of a specific printed circuit board.
This kind of knowledge can be important to a manufacturer to conduct targeted callbacks or to es-
tablish damage claim against suppliers. 7
This option allows you to generate traceability data during production on all mentioned ma-
chines. 7
7.6.2 Functionality
Each printed circuit board engaged into the machine is identified with the help of the printed circuit
board barcode reader. 7
The machine knows the setup and the currently used component batches. Via the internal in-line
assembly information the machine recognizes which batches were used to assemble the
particular printed circuit board. In case a batch is exchanged (Refill), the operator records the
information about the new batch with a barcode reader. The machine is able to recognize batch
changes either through splice recognition or the counting of level indicators.
All collected data for a printed circuit board are finally combined into a data package and
exported through the Traceability interface. 7