00193325-01.pdf - 第61页

SIPLACE Software Guide SR.503.xx 4 Switching the SIPLACE line on and off Issue 12/01 E N 4.1 Switching on the SIPLACE line 61 4.1. 3 W hat to c heck b efor e swit chin g on the stations CAUTION Carry out t he steps d esc…

100%1 / 124
4 Switching the SIPLACE line on and off SIPLACE Software Guide SR.503.xx
4.1 Switching on the SIPLACE line Issue 12/01 EN
60
4.1.2 Switching on the line computer (Windows NT with SIPLACE Pro LC software)
/ Starting the SIPLACE Pro user interface
Switch on the line computer. Once the computer has started a Windows NT login window ap-
pears.
Log on to your domain by entering your user name and password.
Start SIPLACE Pro from the Windows NT Start menu:
Start --> Programs --> Siemens SIPLACE
or
Start SIPLACE Pro
by clicking the icon on your desktop.
The system then connects to SIPLACE ProServer and opens up the SIPLACE Pro user interface.4
While you are waiting for the system to connect to the SIPLACE ProServer you will see the fol-
lowing screen. 4
4
Fig. 4.1 - 1 Starting SIPLACE Pro
SIPLACE Software Guide SR.503.xx 4 Switching the SIPLACE line on and off
Issue 12/01 EN 4.1 Switching on the SIPLACE line
61
4.1.3 What to check before switching on the stations
CAUTION
Carry out the steps described below before switching on the stations. 4
Check to make sure that the stations are connected to both the power supply and to the com-
pressed air supply.
Carry out a visual inspection of the stations. In particular, make sure that there are no obstruc-
tions in the traveling range of the gantries.
Make sure that the z-axes of all heads are in the top end position.
Close the feeder covers and the protective covers.
Make sure that there is no diskette in the disk drive of the station computer.
4 Switching the SIPLACE line on and off SIPLACE Software Guide SR.503.xx
4.1 Switching on the SIPLACE line Issue 12/01 EN
62
4.1.4 Switching on the station / Starting the user interface of the station computer
program
CAUTION
Only switch on the station after the desktop is displayed on the line computer monitor. Otherwise,
communication problems may occur. 4
Switch on the station at the main switch and check to see if the manometer displays the re-
quired operating pressure after you have switched the station on.
The station computer software is loaded. If a line computer is connected and communication
is error-free, the Main view of the station computer user interface for the „Operator“ user class
appears after approximately 2 minutes (see Fig. 4.1 - 2).
4
Fig. 4.1 - 2 Main view after loading the station computer software (Example: HS-50)