00193325-01.pdf - 第64页
4 Switching the S IPLACE line on and off SI PLACE Sof tware Guide SR.503.xx 4.1 Switching on the SIPLACE line Issue 12/ 01 EN 64 4 Fig. 4.1 - 3 "Switching on th e SIPLACE line" flow chart Nozzle check If necess…

SIPLACE Software Guide SR.503.xx 4 Switching the SIPLACE line on and off
Issue 12/01 EN 4.1 Switching on the SIPLACE line
63
NOTE
The current state of the station is displayed in the status field in the „Status“ line, and the action
you are to execute is displayed in the „Action:“ line (see Fig. 4.1 - 2). 4
When the „Press start button“ prompt appears, press one of the start buttons (weiß für HS-50
und grün bei S25 HM).
(The start buttons are located on the input side, output side and on the control panels on the
left and right sides of the station - HS-50 only.)
A reference run is executed on all axes. The station is ready for operation after the reference
run has been completed.
The symbol is displayed in the work area of the user interface.
4
4
4.1.5 "Switching on the SIPLACE line" flow chart
The following flow chart shows the actions executed by the line computer, station and operator
while the SIPLACE line is being switched on and started up. 4

4 Switching the SIPLACE line on and off SIPLACE Software Guide SR.503.xx
4.1 Switching on the SIPLACE line Issue 12/01 EN
64
4
Fig. 4.1 - 3 "Switching on the SIPLACE line" flow chart
Nozzle check
If necessary, change
nozzle configuration
Test set-up
Set tracks to full
No
Line computer tasks
Load cluster data
Fiducials
OK?
Make settings on the machine
Set-up generator appears
Check the set-up
(attach feeder modules)
Switch on
Wait for PCB
Introduce PCB
Track errors
Yes
Abort
placement
No
PCB to output conv.
Yes
Station computer
Bold type:
Italic type:
To be carried out by the
operator
Carried out or signaled
by the station
Confirm the
set-up generator

SIPLACE Software Guide SR.503.xx 4 Switching the SIPLACE line on and off
Issue 12/01 EN 4.2 Switching off the SIPLACE line
65
4.2 Switching off the SIPLACE line
CAUTION
Before you switch off the line, ALWAYS make sure that: 4
– All placement operations on the stations have been completed
– The z-axis of all placement heads are in the top end position
– None of the placement heads still contain components
– All gantries have moved into the standby position
– The station computers have been properly shut down.
4.2.1 Switching off the line computer (UNIX)
CAUTION
NEVER just switch off the line computer at the power switch (UPS).
ALWAYS shut down the operating system of the line computer with „Shutdown“. Otherwise you
will almost certainly lose a lot of data and may even need to reinstall the line computer software.4
Position the mouse at the right or lower edge of the screen.
The cursor will change into a cross.
Press and hold down the left mouse button. The main menu appears.
Move the mouse cursor onto the 'Shutdown' menu item and then release the mouse button.
The following dialog box appears on screen:
Click Yes. The dialog box closes and the operating system is shut down. This operation takes
around 1 minute. The following message then appears:
Switch off the UPS.
Really shutdown?
Yes No
** Safe to Power Off **
-or-
** Press Any Key to Reboot **