00192471-03.pdf - 第21页
User Manual SIPLAC E HS-50 1 Introduction Software Vers ion SR.50x.xx 01/2006 US Edition 1.10 Connection data for the placement syst em 21 DANGER The placem ent sy stem is sup plied with 3 x 204 V AC (US ve rsion), 3 x 2…

1 Introduction User Manual SIPLACE HS-50
1.10 Connection data for the placement system Software Version SR.50x.xx 01/2006 US Edition
20
1.10 Connection data for the placement system
1.10.1 Electrical and pneumatic connection points on the placement system
1
Fig. 1.10 - 1 Electrical and pneumatic connection points on the placement system
(1) Operating panel, left
(2) Main switch
(3) Safety doors to the power supply unit
(4) Hole for the power cable
(5) Operating panel, right
(6) Safety door to the compressed air unit
(7) Hole for the compressed air line
(8) LAN connection on the station computer

User Manual SIPLACE HS-50 1 Introduction
Software Version SR.50x.xx 01/2006 US Edition 1.10 Connection data for the placement system
21
DANGER
The placement system is supplied with 3 x 204 V AC (US version), 3 x 230 V AC, 3 x 380 V AC,
3 x 400 V AC or 3 x 415 V AC ± 5 %, 50/60 Hz mains voltage. This means that some parts of the
system carry potentially lethal voltages - even when switched off at the main switch. Incorrect han-
dling of the placement system can therefore result in death or severe injury or considerable dam-
age to equipment. 1
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 1
1.10.2 Technical data - electrical ratings
1
Supply voltage 3 x 204 VAC ± 5 %; 50/60 Hz (U.S.A)
3 x 230 VAC ± 5 %; 50/60 Hz
3 x 380 VAC ± 5 %; 50/60 Hz
3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 415 VAC ± 5 %; 50/60 Hz
Fuses 3 x 32 A (3 x 204 VAC)
3 x 32 A (3 x 230 VAC)
3 x 16 A (3 x 380 VAC)
3 x 16 A (3 x 400 VAC)
3 x 16 A (3 x 415 VAC)
Total connected load 11.1 kVA
Total output 9 kW
Power failure max. 10 msec

1 Introduction User Manual SIPLACE HS-50
1.11 Technical data - compressed air supply Software Version SR.50x.xx 01/2006 US Edition
22
1.11 Technical data - compressed air supply
1.11.1 Technical data - compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1) 1
1.11.2 Technical data - noise emissions
1.11.3 Technical data - admissible environmental influences
Compressed air pressure supply min 6.5 bar
Compressed air consumption 950 Nl/min.
Operating pressure 5.5 bar ± 0.5 bar
Particle size 0.1 µm
Particle density 0.2 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Dew point under pressure (class 4) Dew point +3°
Maximum noise generation 74 dB (A)
Ambient temperature Between 15°C and 35°C
Atmospheric humidity 30 to 75%
(but no higher than 45% on average in order to prevent
any possibility of condensation on the machine.)