User Manual SIPLAC E HS-50 2 Oper ational Safety Software Vers ion SR.50x.xx 01/2006 US Edition 2.5 Energy state of the placement s ystem after swit ching off at the m ain switch 83 2.5 Energy st ate of the place ment sy…

2 Operational Safety User Manual SIPLACE HS-50
2.4 Disabling the compressed air supply and releasing the pressure Software Version SR.50x.xx 01/2006 US Edition
82
2
Fig. 2.4 - 1 Compressed air unit on the placement system
WARNING 2
NEVER detach compressed air lines while they are still pressurized. Risk of injury.
(1) Shut-off valve lever in the CLOSED position
(2) Operating pressure gauge
(3) Pressure gauge for the component table operating pressure
(4) Input pressure manometer
(5) Position of the compressed air unit on the placement system

User Manual SIPLACE HS-50 2 Operational Safety
Software Version SR.50x.xx 01/2006 US Edition 2.5 Energy state of the placement system after switching off at the main switch
83
2.5 Energy state of the placement system after switch-
ing off at the main switch
DANGER 2
The placement system is supplied with 3 x 204 V AC (US version), 3 x 230 V AC, 3 x 380 V AC,
3 x 400 V AC or 3 x 415 V AC ± 5 %, 50/60 Hz mains voltage. This means that some parts of the
system carry potentially lethal voltages - even when switched off at the main switch. Incorrect
handling of the placement system can therefore result in death or severe injury or considerable
damage to equipment.
Æ Always follow the applicable accident prevention and DIN regulations (particularly DIN 60 204,
part 1).
Æ The cover over the servo unit must only be opened by qualified and trained personnel.

2 Operational Safety User Manual SIPLACE HS-50
2.5 Energy state of the placement system after switching off at the main switch Software Version SR.50x.xx 01/2006 US Edition
84
2
Fig. 2.5 - 1 Position of the servo unit, main switch, service socket and compressed air unit
on the placement system
2
(1) Main switch
(2) Service socket behind the safety doors
(3) Compressed air unit
(4) Servo unit
(5) Measuring unit in the servo unit