Adjustment Instructions SIPLACE HS -50 6 Gantries Edition 05/00 6.5 D ynamic Adjustment of the X - and Y- A xes 123 &RQWURORIWKH ;$ [LV '\ QDPLFV *HQHUDO3UHS DUDWLRQV Å Make sure tha t the …

6 Gantries Adjustment Instructions SIPLACE HS-50
6.5 Dynamic Adjustment of the X- and Y- Axes Edition 05/00
122
0 HDVXUHPHQW6HWXSIRU$[LV$GMXVWPHQW V
NOTE
The current value measured at the adapter board is actual, not (commuted) nominal.
axis 2
Vnominal
ready for operation
enable output stage
effective current limit
error
interface
test adapter
axis test box
interface
axis
control card
interface
axis
test box
changeover switch pressed down
end signal axis 2
end signal axis 0
dev
iation
of pos
ition
nom
inal current
end
signal
track A track B zero pulse Vnom force end signal deviat. of pos.
dgt
zero pulse
end signa
l
axis 0
axis 1
axis 2
OFF
ON
synchronization
axis 0
axis 1
axis 2

Adjustment Instructions SIPLACE HS-50 6 Gantries
Edition 05/00 6.5 Dynamic Adjustment of the X- and Y- Axes
123
&RQWURORIWKH;$[LV'\QDPLFV
*HQHUDO3UHSDUDWLRQV
Å Make sure that the belt tension is correctly adjusted to 53 Hz +1 / -3 Hz.
Å Start SITEST.
Å Switch on the compressed air supply.
Å Make sure that all friction surfaces are clean.
Å Prepare the measurement setup for the x-axis. (See fig 6.5 - 3).
Å Set the oscilloscope according to the values of the table below.
Å Perform a head reference run.
Å Perform a gantry reference run.
NOTE
Use an RC - filter to record the current curve.
Measure the end signal on the adapter board "axis test box", with the switch pressed down.
&RQWURO3*DLQ
NOTE
Adjustment of the gantry axes on the servo amplifier is not possible.
Adjustment parameters are preset through board VC10.
This board is positioned on the axis control cards 1, 2, 3 and 4.
The nominal current of the x-axis must be measured at the "measuring adapter axis control card,
measuring pin axis 0".
(Do not connect GND).
6,7(67
Å Select "Gantry" ==> ==> "Select gantry" ==>
"Axis functions" ==> "Select x-axis" ==> "Adjust P-gain" ==>
"Select travel range with the help of the ÇÆ arrow buttons" ==> "End" ==> "Abort".

6 Gantries Adjustment Instructions SIPLACE HS-50
6.5 Dynamic Adjustment of the X- and Y- Axes Edition 05/00
124
2VFLOORVFRSH6HWWLQJV
&KDQQHO 6LJQDO &RXSOLQJ <'HIOHFWLRQ 7ULJJHU ;'HIOHFWLRQ
CH1 Vnominal DC 0.1 V/ DIV
CH 1
positive
10% pre
10 ms/ DIV
CH2 deviat. of pos. DC 0.5 V/ DIV
CH3 nominal current DC 0.2 V/ DIV
Ch4 end signal DC 5.0 V/ DIV
Sollwert /
Vnominal
Positionsabweichung
deviation of position
Kraftsollwert /
nominal current
Endemeldung /
end signal
&KDQQHO 6LJQDO &RXSOLQJ <'HIOHFWLRQ 7ULJJHU ;'HIOHFWLRQ
CH1 Vnominal DC 1.0V/ DIV
CH 1
positive
3% pre
10 ms/ DIV
CH2 deviat. of pos. DC 0.5 V/ DIV
CH3 nominal current DC 5.0V/ DIV
Ch4 end signal DC 5.0 V/ DIV