172 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx) Adjustment Instructions HS-50 9.6 Calibration Collect & Place H ead Nozzle Changer Software-Version 5.01 E dition 05/00 NOTE The pick-up height…

Adjustment Instructions HS-50 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx)
Software-Version 5.01 Edition 05/00 9.6 Calibration Collect & Place Head Nozzle Changer
171
&DOLEUDWLRQ&ROOHFW3ODFH+HDG1R]]OH&KDQJHU
&RPSOHWH&DOLEUDWLRQ
Example: Nozzle changer for C&P Head 1, completely supplied with all 5 or 10 magazines.
6,7(67
Å Select "C&P Heads" ==> "C&P Head 1" ==>
"C&P Head nozzle changer" ==> "Complete calibration".
Å Proceed under section "Calibration of the Pick-Up Height". (See section 9.6.3).
NOTE
Make sure that the calibration data for the
PCB camera, the segment offset II (C&P
PCB camera offset) and the machine zero
point have been determined already.
NOTE
A nozzle changer contains 5 magazines
maximum, with 12 nozzle garages each.
For every single C&P Head, 2 nozzle
changers may be installed. During
calibration these will be handled like one
single nozzle changer with 10 maga-
zines.
NOTE
The function "Complete calibration" is
used, if the nozzle changer is completely
loaded with all 5 or 10 magazines.
All 12 nozzles must be on the C&P Head.
With the help of the function "Calibrate
current magazine", x- and y-values must
be individually determined for each
magazine if the changer is not
completely
loaded.

172
9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx) Adjustment Instructions HS-50
9.6 Calibration Collect & Place Head Nozzle Changer Software-Version 5.01 Edition 05/00
NOTE
The pick-up height must be determined for
each magazine.
&DOLEUDWLRQRIWKH&XUUHQW0DJD]LQH
Example: Nozzle changer for C&P Head 1, not completely loaded with all magazines.
6,7(67
Å Select "C&P Heads" ==> "C&P Head 1" ==>
"C&P Head nozzle changer" ==> "Magazine number..." ==> "Type in magazine number and
accept" ==> "Calibrate current magazine".
Å Repeat these instructions with all magazines.
Å Proceed under section "Calibration of Pick-Up Height". (See section 9.6.3).

Adjustment Instructions HS-50 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx)
Software-Version 5.01 Edition 05/00 9.6 Calibration Collect & Place Head Nozzle Changer
173
&DOLEUDWLRQRI3LFN8S+HLJKW
Å Ascertain, that there is a nozzle on the lower segment, and that all garages selected below, are empty.
6,7(67
Å Select "Magazine number..." ==> "Type in magazine number and accept" ==> "Garage number..." ==>
"Type in garage number and accept" ==> "Calibrate pick-up height" ==> "OK".
Å Repeat this procedure for all magazines.
Å Select "Main View" ==> "Save machine data".
NOTE
Each individually determined pick-up
height (z-position) will be displayed in a di-
alogue box, after the calibration.
The z-position of the reject container will
be calculated from the pick-up height
determined for the last magazine.
If you want to test if the calibration was
successful, you should always FIRST
save the determined calibration data
("Main view" ==> "Settings" ==> "Save
machine data"). After saving the data,
return to the display "C&P Head nozzle
changer".
With the help of the functions "Place / Pick-
up" you can test the calibration result.