HS50的结构及原理.pdf - 第88页
4 Overview Voltages Adjustment Instructions SIPLACE HS-50 4.6 Measuring Voltages of the Power Supply Unit Edition 05/00 88 NOTE Pin confi guration of singl e connect ors can be checked in the d etailed cir cuit diagra m,…

Adjustment Instructions SIPLACE HS-50 4 Overview Voltages
Edition 05/00 4.6 Measuring Voltages of the Power Supply Unit
87
&RQQHFWRU3OXJ3DQHORI3RZHU6XSSO\ 8QLW
.(<
0RGXOH &RQQHFWLQJFODPSV 9ROWDJHV
Mains filter L1, L2, L3 3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
Electrolyt capacitor C1 + / - 50 VDC
T1 Rotary current transformer, 11,1 kVA
P200 V Screw connection M6 (+) for the supply of the servo amplifier of the x /y - axes
N200 V Screw connection M8 (-) for the supply of the servo amplifiers of the x /y - axes
X2 to PC
X3 to monitor 1
X4 to monitor 2
X5 to lifting table 1, PCB conveyor 1
X6 to lifting table 2, PCB conveyor 1
X7 to lifting table 3, PCB conveyor 2 (option)
X8 to lifting table 4, PCB conveyor 2 (option)
X9 to servo unit
X10 to main distributor (unsaturated DC voltages)
X11 to PCB handling / to lifting table control
X12 from / to main distributor, (control signals, power supply)
X13 from / to main distributor, (PCC - peripheral unit)
P 200 VDC
N 200 VDC

4 Overview Voltages Adjustment Instructions SIPLACE HS-50
4.6 Measuring Voltages of the Power Supply Unit Edition 05/00
88
NOTE
Pin configuration of single connectors can be checked in the detailed circuit diagram, section 3.

Adjustment Instructions SIPLACE HS-50 5 Single and Dual PCB Conveyor
Edition 05/00 5.1 Settings and Illustrations
89
6LQJOHDQG'XDO3&%&RQYH\RU
6HWWLQJVDQG,OOXVWUDWLRQV
6/,20RGXOH,20RGXOHVDQG3 &%&RQYH\RU
NOTE
6/,2 = 6erialOinked ,N- / 2 utput
SLIO - Modul 1
SLIO module 1
SLIO - Modul 2
SLIO module 2
SLIO - Modul 3
SLIO module 3
SLIO - Modul
4
SLIO module 4
SLIO - Modul 5
SLIO module 5
SLIO - Modul
6
SLIO module 6