Adjustment Instructions HS-50 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx) Software-Version 5.01 Edition 05/00 9.2 Calibration of PCB - Camera 167    &DOLEUDWLRQRI 3&%&DPHUD Exampl e…

100%1 / 182
166
9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx) Adjustment Instructions HS-50
9.1 Preparations for Calibration Software-Version 5.01 Edition 05/00
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
10
9
8
7
6
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
2
3
4
5
.(<
(1) Calibration tool, placement position 1
(2) Fixed PCB corner
(3) Nozzle changer magazine
(4) Placement area 2
(5) Placement area 2
NOTE
Some calibrations require that you attach
ozzles on the placement heads.
Use nozzles of type .
Make sure that all nozzles have been
attached correctly, otherwise measuring
will lead to incorrect results.
If you need to, place the calibration tool
into the "calibration bag".
(See fig 9 - 1
).
Before you place the calibration tool, make
sure that it is clean. Also, be sure that you
insert it into the "calibration bag" with its
print of the fiducial structure on the bot-
tom.
 3UH SDUDWLRQVIRU&DOLEUDWLRQ
Å Start SITEST.
Å Under menu item "Main view", click "Overall reference run", to reference all gantry- and head- axes.
Adjustment Instructions HS-50 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx)
Software-Version 5.01 Edition 05/00 9.2 Calibration of PCB - Camera
167
 &DOLEUDWLRQRI3&%&DPHUD
Example: PCB - camera, gantry 1
Å Insert the calibration tool into the "calibration bag 1" in placement area 1.
(See
fig 9 - 1).
6,7(67
Å Select "Gantry" ==> "Gantry 1" ==> "PCB - camera functions" ==>
"Calibrate camera" ==> "Main view" ==> "Save machine data".
NOTE
Repeat these instructions in order to
calibrate the PCB - cameras of gantries
2, 3 and 4.
NOTE
With the help of the function "Display
camera coefficient", the determined
values can be displayed after you finished
calibration.
The value under "Angle [1 / 100°] must not
exceed 100.
168
9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx) Adjustment Instructions HS-50
9.3 Calibration of the Collect & Place Head Software-Version 5.01 Edition 05/00
NOTE
Repeat these instructions in order to
calibrate the C&P Heads 2, 3 and 4.
For the calibration follow these steps:
Calibration of the PCB - camera
Calibration of the C&P - camera
Determination of the segment offsets I
for all 12 segments
Determination of the segment offsets II
for all 12 segments and the C&P
PCB camera offset, relating to
segment I.
NOTE
With the help of the function "Display
camera coefficient", the determined val-
ues can be displayed after you finished
calibration.
Segment offset I: No deviation > 120 µm
between the individual segments and no
value for a single segment > 450 µm
allowed!
Segment offset II: The value for segment 1
is always 0.
 &DOLEUDWLRQRIWKH&ROOHFW3ODFH+HDG
Example: C&P Head 1
Å Insert the calibration tool into the "calibration bag 1" in placement area 1. (See fig 9 - 1).
Å Place 12 nozzles, type 956 on the star.
6,7(67
Å Select "C&P Heads" ==> "C&P Head 1" ==> "C&P Head and camera" ==>
"Calibrate camera" ==> "Main view" ==> "Save machine data".