Adjustment Instructions SIPLACE HS -50 2 Operational Safety Edition 05/00 2.5 Energy Level after Sw itching Off Main Switch 53  3OD FHPHQW 6\ VWHP6ZLWFKHG2IIDWWKH0DLQ6ZLWF KDQG'LVFRQQH FWHG The automa…

100%1 / 182
2 Operational Safety Adjustment Instructions SIPLACE HS-50
2.5 Energy Level after Switching Off Main Switch Edition 05/00
52
 3ODFHPHQW6\VWHP6ZLWFKHG2IIDWWKH0 DLQ6Z LWFK EXW6 WLOO &RQQHFWHG
The following table specifies the voltages of modules when the placement system is switched off
at the main switch, but still remains connected to the mains supply.
DANGER
The following components still carry potentially lethal voltages even if the main switch is switched
off:
Cable connection terminals 1, 3, and 5 of S1 main switch,
Z1 mains filter,
BU1 service socket,
F1 automatic circuit breaker for the service socket.
The color of all single wires, which still carry potentially lethal voltages even if the main switch
is switched off is brown.
0RGXOH 9ROWDJH
Mains filter Z1
Terminals L1, L2, L3
3 x 204 V AC
3 x 230 V AC
3 x 380 V AC
3 x 400 V AC
3 x 415 V AC
Service socket BU1
115 V AC
130 V AC
220 V AC
230 V AC
240 V AC
Circuit breaker F1
115 V AC
130 V AC
220 V AC
230 V AC
240 V AC
Adjustment Instructions SIPLACE HS-50 2 Operational Safety
Edition 05/00 2.5 Energy Level after Switching Off Main Switch
53
 3OD FHPHQW 6\VWHP6ZLWFKHG2IIDWWKH0DLQ6ZLWFKDQG'LVFRQQH FWHG
The automatic placement system is cut off from all electricity , apart from slight residual voltages
in the servo unit.
 &RPSUHVVHG$LU&RQGLWLRQVLQWKH0DFKLQHDIWHU6ZLWFKLQJ2IIWKH0 DLQ
6ZLWFK
When the system is switched off at the main switch (item 1 in fig. 2.4 - 1) or if the power supply
fails, the electrically controlled main valve Y1 of the compressed air unit closes.
(Item 3 of fig. 2.4 - 1
). The pressure will drop to 0 bar within 5 seconds.
Main switch S1
Terminals 1, 3, 5
3 x 204 V AC
3 x 230 V AC
3 x 380 V AC
3 x 400 V AC
3 x 415 V AC
Servo unit (See item 5 of fig. 2.5 - 1
)
Test socket X2
Test socket X3
Test socket X4
GND X1
< 10 VDC
< 10 VDC
< 10 VDC
Control unit (See item 3, 4, 5 and 6 of fig. 2.5 - 2
)
Test socket + 12 VDC (x3ta)
Test socket - 12 VDC (x4ta)
Test socket + 15 VDC (x3tb)
Test socket -15 VDC (x4tb)
Test socket + 5 VDC (x3td)
Test socket + 24 VDC (x4td)
Test socket + 50 VDC (x5te)
Test socket + 5 VDC (x4te)
GND (x3td)
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
2 Operational Safety Adjustment Instructions SIPLACE HS-50
2.6 Locking Up of Machine and Tagging of Warn Signs Edition 05/00
54
/RFNLQJ8SRI0DFKLQHDQG7DJJLQJRI:DUQ6LJQV
 3XUSRVHDQGVFRSH
Before performing any maintenance work or service work, a procedure of locking and tagging
must be followed. The procedure, when followed correctly eliminates the possibility of an
employee being injured.
NOTE
These procedures represent the minimum lock / tag out requirements.
Any additional safe - guards needed to complete work safely can be specified by supervision fa-
cilities, the safety officer, the safety committee and the health department.
 'HVFULSWLRQ
Whenever it becomes necessary to isolate, control and release energy, the following procedure is
to be followed
(1) Notify all involved employees.
(2) Shut down the system and all equipment, using normal stopping procedures, such as
pressing the STOP button
shutting down the station computer or
switching off the placement system at the main switch.
(3) Isolate the equipment from all its energy sources such as
compressed air supply and
power supply.
(4) Lock up the system
Fasten a lock wherever possible, e.g. on the
motor protection switch.