HS50的结构及原理.pdf - 第180页
180 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx) Adjustment Instructions HS-50 9.10 Determination of T raversing Paths of Gantry Axes Software-Version 5.01 Edition 05/00 6,7(67 Å Select "Gantry&…

Adjustment Instructions HS-50 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx)
Software-Version 5.01 Edition 05/00 9.10 Determination of Traversing Paths of Gantry Axes
179
6,7(67
Å Select "Gantry" ==> "Gantry 1(4) ==> "Axis Functions" ==> "X-Axis" ==>
"Positions...".
Å Edit this value for the actual current position of the X-axis under "Maximum position [dgts]" and
accept the value.
Å Select "Reference run" ==> "Main View" ==> "Save machine data".
0LQLPXP7UDYHUVLQJ3DWK;$[LV*DQWU\
Å Manually, move the gantry 1 (4) towards the deflection unit X, until both proximity switches are off.
Å Now, manually move gantry 1 (4) towards the X-motor, until a proximity switch just is on.

180
9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx) Adjustment Instructions HS-50
9.10 Determination of Traversing Paths of Gantry Axes Software-Version 5.01 Edition 05/00
6,7(67
Å Select "Gantry" ==> "Gantry 1 (4) ==> "Axis Functions" ==> "X-axis" ==>
"Positions ...".
Å Edit the value for the current position of the x-axis under "Minimum position [dgts]" and accept the value.
Å Perform a reference run.
Å Select "Main View" ==> "Save machine data".
0D[LPXP7UDYHUVLQJ3DWK;$ [LV*DQWU\
Å Manually, move gantry 2 (4) towards deflection unit-X, until both proximity switches are off.
Å Now, manually move gantry 1 (4) towards the x-motor, until a proximity switch is on.
6,7(67
Å Select "Gantry" ==> "Gantry 2 (4) ==> "Axis Functions" ==> "X-axis" ==>
"Positions ...".
Å Edit the value for the current position of the x-axis under "Maximum position [dgts]" and accept the value.
Å Perform a reference run.
Å Select "Main View" ==> "Save machine data".
0LQLPXP7UDYHUVLQJ3DWK;$[LV*DQWU\
Å Manually, move gantry 3 (4) towards the deflection unit-X, until both proximity switches are off.
Å Now, manually move gantry 3 (4) towards the x-motor, until a proximity switch just is on.
6,7(67
Å Select "Gantry" ==> "Gantry 3 (4) ==> "Axis Functions" ==> "X-axis" ==>
"Positions ...".
Å Edit the value for the current position of the x-axis under "Minimum position [dgts]" and accept the value.
Å Perform a reference run.
Å Select "Main View" ==> "Save machine data".

Adjustment Instructions HS-50 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx)
Software-Version 5.01 Edition 05/00 9.11 Save Machine Data
181
6DYH0DFK LQH'DWD