2 Operational Safety Adjustment Instructions SIPLACE HS-50 2.2 Safety Equipment E dition 05/00 30 )XQFWL RQ If one of the p rotectiv e cover s is folded up or one of the c overs o n the PCB c onveyor is raise d, the powe…

Adjustment Instructions SIPLACE HS-50 2 Operational Safety
Edition 05/00 2.2 Safety Equipment
29
6 DIHW\(TXLSPHQW
3URW HFWLYH&RYHUV
.(<
The travelling range of the gantries is covered by four protective covers which can be folded up.
Side panels prevent access to the inside of the placement system from the side. The covers over
the input and output belts of the PCB conveyor and the guards on the input and output belts
prevent access to the PCB conveyor.
(1) Protective covers
(2) Safety panels
(3) Cover and guard on the input conveyor
(4) Cover and guard on the output conveyor

2 Operational Safety Adjustment Instructions SIPLACE HS-50
2.2 Safety Equipment Edition 05/00
30
)XQFWL RQ
If one of the protective covers is folded up or one of the covers on the PCB conveyor is raised, the
power supply to the gantry axes will be interrupted at once. The gantry axes will stop.
– The message "Close covers" will appear on screen.
Å Close the protective covers and press one of the START buttons to continue placement.
.(<
(1) START button (white) on the system

Adjustment Instructions SIPLACE HS-50 2 Operational Safety
Edition 05/00 2.2 Safety Equipment
31
*XDUGRQWKH,QSXW2XWSXW&RQYH\ RU
DANGER
The guard must always be set to the height of the PCB to be processed. Ensure that the gap
between the guard and the safety bar is as small as possible.
– Guards are fitted on the input and output belts of the PCB conveyor.
Å The height of the guard must be set using the slots so that the processed PCB can travel
through.
.(<
(1) Safety bar (fixed)
(2) Guards (adjustable)
(3) Slots for adjusting the height
(4) Cover