00197467-01_SM_DLM3-4_Kunde_en.pdf - 第61页
Service Work 3.17.3 Replacing the Silicone Hoses on the Star [0034 1183S01] Re placing the Membrane (Vacuum Plate) on the Sleeve [030 37984-xx] Service Manual SIPLACE Placement Heads DLM3/DLM4 61 3.22 3 . 2 2 R e p la c …

Service Work
Press-fit Connections with Fixture Clips on the Vision Board 3.17.3 Replacing the Silicone Hoses on the Star [00341183S01]
60 Service Manual SIPLACE Placement Heads DLM3/DLM4
3.20
3.20 Press-fit Connections with Fixture Clips on the Vision Board
Press-fit Connections with Fixture Clips on the Vision Board
3.21
3.21 Replacing the Raceway (Circular Arc Guide)
Replacing the Raceway (Circular Arc Guide)
CAUTION
Do not damage the fixture clips!
To disconnect the component and PCB camera connections, you need to open the fixture clips
by applying pressure to the side of the connector.
► To release the press-fit connections, press the con
-
nector sides together at the top, with your thumb and
index finger.
The fixture clips will open and the connector can be
pull up and off.
The adjacent diagram shows 2 such connections after
the connector has been unplugged.
NOTICE
SIPLACE Service
This service task may only be performed by specially trained SIPLACE service technicians. The
procedure is described in a separate manual.

Service Work
3.17.3 Replacing the Silicone Hoses on the Star [00341183S01] Replacing the Membrane (Vacuum Plate) on the Sleeve [03037984-xx]
Service Manual SIPLACE Placement Heads DLM3/DLM4 61
3.22
3.22 Replacing the Membrane (Vacuum Plate) on the Sleeve [03037984-xx]
Replacing the Membrane (Vacuum Plate) on the Sleeve
[03037984-xx]
The sealing membrane on the sleeves ensures sufficient vacuum by sealing the tip of the nozzle (serves
as the air inlet) in the sleeve.
Parts, equipment and tools
▪ Membrane (suction plate) [03037984-xx] (new version)
Removal
► Loosen the old membrane with an Allen key (1.5 mm) and remove the membrane.
Installation
► Fit the new membrane onto the sleeve and tighten the membrane with an Allen key.
Blue membrane for the sleeve with ball fixing
(old version [00354244-xx])
White membrane for the sleeve with ball fixing, made of
an alternative material
(new version [03037984-xx])
NOTICE
Removal of head not required
You do not need to remove the head when replacing the membrane.
CAUTION
Do not use a ball Allen key!
► Do not use a ball Allen key.

Service Work
Replacing the Vacuum Hoses on the Head 3.17.3 Replacing the Silicone Hoses on the Star [00341183S01]
62 Service Manual SIPLACE Placement Heads DLM3/DLM4
3.23
3.23 Replacing the Vacuum Hoses on the Head
Replacing the Vacuum Hoses on the Head
The length of the vacuum hoses and the way in which they are fitted has been improved to ensure that,
when the hoses are replaced - especially in SX, DX, X, D3 and HF machines - these hoses can be run
in a manner which will not interrupt the vacuum supply.
Parts, equipment and tools
▪ Vacuum hoses and guidance [03064147-xx]
Contents:
– Hose for placement circuit query (new length: 180 mm, old length: 190 mm) [03002187-02]
– Hose for holding circuit query (new length: 225 mm, old length: 200 mm) [03002188-02]
– Hose for placement circuit / 3x6x145 (new length: 145 mm, old length: 125 mm) [03010444-02]
– Hose for hold circuit / 4x7x140 [03010445S01]
– Hose guide [03048807-01]
– Cylinder screw M3x6 DIN912-A2 [03045028-01]
Preparation
► Remove the head from the machine. For details about removing and fitting the placement head, refer
to the service manual for your machine.
Removal
► Disconnect the hoses from the vacuum generator and the vacuum measuring board.
Installation
► Fit the additional hose guide (M3 screw) on the top measuring hose duct.
► Fit the new hose as shown in the diagrams.
► Further installation is performed by following the above instructions in the reverse order.
CAUTION
Mark the connection points and the route of the hoses
Mark the connection points and the route of the individual hoses, so that these can be rerun
correctly later on.