00197467-01_SM_DLM3-4_Kunde_en.pdf - 第78页

Settings DLM4 Assembly with adapter plate 78 Service Manual SIPLACE Placement Heads DLM3/DLM4 5.10 5 . 1 0 D L M 4 A s s e m b ly w it h a d a p t e r p la t e DLM4 Assembly with adapter plate The screw s fastening the D…

100%1 / 88
Settings
Vacuum Test
Service Manual SIPLACE Placement Heads DLM3/DLM4 77
Scenario 2
Example of defective vacuum values, which indicate a
damaged silicone hose on segment 1 and an open nozzle
at segment 3.
NOTICE
Silicone hose defect
Under certain circumstances, silicone hose defects might only be detected when the segments
are moved out. It could therefore be advisable to release the Z axis and to perform a vacuum
test of the segment in its lowered state (single measurement run).
NOTICE
Missing valve plunger
If both measurements for a particular segment are only around 210mbar, this indicates that the
valve plunger is missing.
Vacuum values and valve plunger positions
If the valve plunger is in position "nozzle open" the
vacuum area is sealed by two seal rings against the
atmosphere.
If the valve plunger is in position "nozzle closed" the
vacuum area is sealed by only one seal ring (at the
rear next to the motor).
If the "vacuum value closed" is too low, this indicates that
the seal is not sufficiently greased or that it is damaged.
Settings
DLM4 Assembly with adapter plate
78 Service Manual SIPLACE Placement Heads DLM3/DLM4
5.10
5.10 DLM4 Assembly with adapter plate
DLM4 Assembly with adapter plate
The screws fastening the DLM4 head must be tightened with a torque of 2.7 Nm to the adapter plate.
The screws fastening the adapter plate must be tightened with a torque of 2.7 Nm to the head mounting
plate of the gantry.
5.11
5.11 Other Mechanical Settings on the Star
Other Mechanical Settings on the Star
Set the blast air tube so that it overlaps the circular guide frame by 0.7 mm.
NOTICE
Replacing the DLM4 head
The DLM4 head can be replaced as part of service work.
If the DLM4 head is fixed to an adapter plate, this will need to be taken off the old head and
fitted to the new one.
Adapter plate DLM4
The adapter plate hardware is designed for quick head
replacement (e.g. for maintenance). It has captive screws
and an eyelet for initial fixation of the head to the head
mounting plate of the gantry.
1. Fastening for DLM4 head on the adapter plate
2. Fastening for adapter plate on the gantry head carrier
3. Loop for fast head exchange (FHE)
4. Centering pins for the DLM4 head
Settings
Firmware Download (SW 70x)
Service Manual SIPLACE Placement Heads DLM3/DLM4 79
5.12
5.12 Firmware Download (SW 70x)
Firmware Download (SW 70x)
The function Firmware Download can be performed
with the operator levels (1) Machine-Service or
SIPLACE-Service.
Switch over to the service menu (2).
Select the button Embedded Software (3).
(1) Select this button to check the entire machine and
to perform an eSW download for multiple subsys
-
tems.
(2) Select this button to select and check one subsys
-
tem, to perform an eSW download.
(3) Select this button to view all versions of the sub
-
systems, BIOS application 1/2.
1. Selection button, BIOS application 1/2
2. Shows the status of the individual subsystems.
3. Update information about the number of subsystems
which still have to be downloaded.
4. Starts the download.