00197467-01_SM_DLM3-4_Kunde_en.pdf - 第71页
Settings Setting the Light Barrier Down Service Manual SIPLACE Placement Heads DLM3/DLM4 71 Setting the Z end stopper Dismantling the star gauge 5.6 5 . 6 S e t t in g t h e L ig h t B a r r ie r D o w n Setting the Ligh…

Settings
Adjusting the Stop for the Z Axis
70 Service Manual SIPLACE Placement Heads DLM3/DLM4
Preconditions
Before you begin adjustment work, check the belt tension and the correct installation of the belt lock at
the Z axis.
Setting
This setting can be performed directly at the machine.
► Switch off the machine.
► For better access to the Z axis end stopper, you should unscrew the cable clamp at one side and
turn it to the side. Then carefully push the flat ribbon cable to the side.
► Check whether the 5/100 mm feeler gauge passes easily (without resistance) between the Z axis
end stopper and the tension jack. If this is not the case, adjust the Z end stopper.
Clamping device Z axis
1. Belt tension Z Axis
2. Tension jack is positioned on the teeth at the top and
bottom
CAUTION!
Make sure that both ends of the tension jack lie on the
teeth of the toothed belt.
Z end stopper star gauge mounted
► Fit the star gauge for setting the Z end stopper on the
head. It is mounted in exactly the same way as the
zero point gauge for the star.
⇨ The star gauge ensures that the star is in the cor
-
rect position and that the Z axis is pressed up
-
wards.
► Remove segment 1 and rotate the star until the
gauge pin fits into the segment guidance.

Settings
Setting the Light Barrier Down
Service Manual SIPLACE Placement Heads DLM3/DLM4 71
Setting the Z end stopper
Dismantling the star gauge
5.6
5.6 Setting the Light Barrier Down
Setting the Light Barrier Down
Z end stopper check and adjust
► Loosen the Z axis end stopper screw (1).
► Clamp the 15/100 mm feeler gauge (2) between the
Z end stopper and the tension jack (3). Gently press
the Z axis end stopper downwards with the screwdriv
-
er and screw tight.
⇨ It should now be more difficult to extract the 15/
100 mm feeler gauge.
► Check again whether the 5/100 mm feeler gauge can
be moved easily (without resistance). If this is not the
case, you will need to repeat the adjustment.
CAUTION
Do not damage it
When removing the gauge, make sure that the gauge pin is extracted first and then the star
gauge. If you do not observe this order, the gauge could catch in the segments and damage
these!
NOTICE
Test probe
The light barrier is set with a test probe to a distance of 1.0 mm to the sleeve.

Settings
Determining the Zero Point Correction for the Star Axis of the C&P Head
72 Service Manual SIPLACE Placement Heads DLM3/DLM4
5.7
5.7 Determining the Zero Point Correction for the Star Axis of the C&P Head
Determining the Zero Point Correction for the Star Axis of the
C&P Head
Flow chart zero point correction
CAUTION!
When performing this task, follow all instructions exactly!