00197467-01_SM_DLM3-4_Kunde_en.pdf - 第62页

Service Work Replacing the Vacuum Hoses on the Head 3.17.3 Replacing the Sili cone Hoses on the Star [00341183S01] 62 Service Manual SIPLACE Placement Heads DLM3/DLM4 3.23 3 . 2 3 R e p la c in g t h e V a c u u m H o s …

100%1 / 88
Service Work
3.17.3 Replacing the Silicone Hoses on the Star [00341183S01] Replacing the Membrane (Vacuum Plate) on the Sleeve [03037984-xx]
Service Manual SIPLACE Placement Heads DLM3/DLM4 61
3.22
3.22 Replacing the Membrane (Vacuum Plate) on the Sleeve [03037984-xx]
Replacing the Membrane (Vacuum Plate) on the Sleeve
[03037984-xx]
The sealing membrane on the sleeves ensures sufficient vacuum by sealing the tip of the nozzle (serves
as the air inlet) in the sleeve.
Parts, equipment and tools
Membrane (suction plate) [03037984-xx] (new version)
Removal
Loosen the old membrane with an Allen key (1.5 mm) and remove the membrane.
Installation
Fit the new membrane onto the sleeve and tighten the membrane with an Allen key.
Blue membrane for the sleeve with ball fixing
(old version [00354244-xx])
White membrane for the sleeve with ball fixing, made of
an alternative material
(new version [03037984-xx])
NOTICE
Removal of head not required
You do not need to remove the head when replacing the membrane.
CAUTION
Do not use a ball Allen key!
Do not use a ball Allen key.
Service Work
Replacing the Vacuum Hoses on the Head 3.17.3 Replacing the Silicone Hoses on the Star [00341183S01]
62 Service Manual SIPLACE Placement Heads DLM3/DLM4
3.23
3.23 Replacing the Vacuum Hoses on the Head
Replacing the Vacuum Hoses on the Head
The length of the vacuum hoses and the way in which they are fitted has been improved to ensure that,
when the hoses are replaced - especially in SX, DX, X, D3 and HF machines - these hoses can be run
in a manner which will not interrupt the vacuum supply.
Parts, equipment and tools
Vacuum hoses and guidance [03064147-xx]
Contents:
Hose for placement circuit query (new length: 180 mm, old length: 190 mm) [03002187-02]
Hose for holding circuit query (new length: 225 mm, old length: 200 mm) [03002188-02]
Hose for placement circuit / 3x6x145 (new length: 145 mm, old length: 125 mm) [03010444-02]
Hose for hold circuit / 4x7x140 [03010445S01]
Hose guide [03048807-01]
Cylinder screw M3x6 DIN912-A2 [03045028-01]
Preparation
Remove the head from the machine. For details about removing and fitting the placement head, refer
to the service manual for your machine.
Removal
Disconnect the hoses from the vacuum generator and the vacuum measuring board.
Installation
Fit the additional hose guide (M3 screw) on the top measuring hose duct.
Fit the new hose as shown in the diagrams.
Further installation is performed by following the above instructions in the reverse order.
CAUTION
Mark the connection points and the route of the hoses
Mark the connection points and the route of the individual hoses, so that these can be rerun
correctly later on.
Measuring Equipment and Tools
Z Axis Gauge (Old) [00331308-xx]
Service Manual SIPLACE Placement Heads DLM3/DLM4 63
4
4 Measuring Equipment and Tools
Measuring Equipment and Tools
4.1
4.1 Z Axis Gauge (Old) [00331308-xx]
Z Axis Gauge (Old) [00331308-xx]
4.2
4.2 RC Filter [02102858-xx]
RC Filter [02102858-xx]
4.3
4.3 Calibration Tool [03010565-xx]
Calibration Tool [03010565-xx]
Use:
The gauge is used to set the top Z axis stopper.
Use:
The RC filter is used for setting the axis dynamics.
Use:
The calibration tool [03010565-xx] is used for calibration
of the DLM, CPP, P&P heads, TwinHead and PCB cam
-
era.