SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.13 Loading and Calibrating SITEST Nozzle Changer RV6 Standard with Nozzles
117
2.13 Loading and Calibrating SITEST Nozzle Changer
RV6 Standard with Nozzles
NOTE:
In SITEST V 502.01 the nozzles on the head and in the nozzle changer are now monitored, as is
the case with the station software.
For the nozzle changer MTC, proceed as described in "Retrofitting instructions MTC on S-25 HM"
(see: Section 2.7). 2
Requirements:
The new placement head(s) DLM1 (6-segment) and the nozzle changer(s) RV6 Standard
must be configured (see: Section 2.10).
All placement heads and cameras must have been calibrated already (see: Section 2.12).
2.13.1 Loading with Nozzles
Å
Starting from the SITEST main view, select
the ICON "Revolver heads" -> and
then "Revolver head 1" or "Revolver head 2" .
Å In the menu "Functions", click on the ICON "Nozzle changer head functions" .
The following will appear on the screen:
2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option) SIPLACE S-23 HM
2.13 Loading and Calibrating SITEST Nozzle Changer RV6 Standard with Nozzles 07/01 Issue
118
Fig. 2.13.1 SITEST: Nozzle Changer Head Functions (Example: RV6)
Å On the 6-segment revolver head, insert one 900 series nozzle and one 800 series nozzle.
In the event that you also measure the nozzle changer RV12:
In case of an 12- segment revolver head it is only necessary to insert a random 900 series noz-
zle on the head.
NOTE:
For RV12-nozzle changer there MUST be ONE large nozzle on the head or in garage 1 of the
magazine in question for the measurement of the large nozzles (800 series). 2
2
2
2
2
2
2
SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.13 Loading and Calibrating SITEST Nozzle Changer RV6 Standard with Nozzles
119
Å Double-click on the line in question as shown on the following screen or select "Edit" (button):
Fig. 2.13.2 SITEST: Nozzle Changer Head Functions, Edit ... Specified Nozzle (Example: RV6)
Å In the window that is opening, "Edit...", select the specified nozzle (e.g., type 920) that is con-
figured in the setup -> Select "Accept" (button).
Å Make this selection for each segment in succession.
Å In conclusion, select "Confirm exchange" (button).