2 Retrofitting Instruct. S-23 HM t o SW V 502. xx incl. RV 6-DLM1 Head (O ption) SIPLACE S -23 HM 2.8 Sequence: M odifying Hardware 07/01 Issue 82 Fig. 2.8.4 Installing Backplane P219 and the Interrupt Connection Å Insta…

100%1 / 126
SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.8 Sequence: Modifying Hardware
81
Fig. 2.8.3 View of the Backplane before Modification
Å Bend the ribbon cable on the 20-pin connector on plug connector X99 (above the SMP board
slot 7) back out the way and - if necessary - unplug the connector.
Å Remove the cover (016) above SMP board slot 8-12: 2 screws M2.5; internal serration T8, see:
Fig. 2.8.3.
2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option) SIPLACE S-23 HM
2.8 Sequence: Modifying Hardware 07/01 Issue
82
Fig. 2.8.4 Installing Backplane P219 and the Interrupt Connection
Å Install the new backplane P219 (from the retrofit kit) above the SMP board slots 8-11, see: fig-
ure above:
While doing so, align the backplane such that the board slots are in a line with those of the SMP
backplane. The connector designations X1-X4 on the back must be at the top.
SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.8 Sequence: Modifying Hardware
83
Å Fasten the backplane with the 8 screws M2.5 from the retrofit kit:
To do so, use 4 screws M2.5 x 10 screws for the top row and 4 screws M2.5 x 8 for the bottom
row.
Å If you unplugged the connector from X99, plug it back in.
Å Plug the connector for the Interrupt TSP-210 machine controller (from the retrofit kit) on the
SMP backplane: To do so, plug the connector cable on the back of SMP board, slot 9, and
board slot 11 onto the plug connectors as shown in Fig. 2.8.4.
Å Re-install the cover 007 (see Fig. 2.8.2).
Å Make certain that none of the cables are pinched or are under tension:
Install the control unit and fasten it with the screw M5.
Fig. 2.8.5 View of the Control Unit after Modification
Å Plug in the 3 new I/O boards KSP-P219-A32 (from the retrofit kit) onto the SMP board slot 8-
10 (see: Fig. 2.8.5).
KSP-P219 (se)
SMP board slot 8
TSP-210
SMP board slot 11
KSP-P219 (sg)
SMP board slot 10
KSP-P219 (sf)
SMP board slot 9