2 Retrofitting Instruct. S-23 HM t o SW V 502. xx incl. RV 6-DLM1 Head (O ption) SIPLACE S -23 HM 2.2 Information Prior t o Upgrading 07/01 Issue 68 this even t, the new 1 5" T ouch Scre en E156 mon itor is o nly in…

100%1 / 126
SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.1 Overview
67
2 Retrofitting Instruct. S-23 HM to SW V
502.xx incl. RV6-DLM1 Head (Option)
2.1 Overview
Only Siemens Dematic SMD Service is permitted to upgrade / retrofit the hardware complete with
the software. This manual describes the upgrading of a SIPLACE S-23 HM (platform 1) to the
SW V 502.xx
(platform 2), on the customers premises. The condition of the supplied machines
must be taken into account for the upgrading during commissioning (e.g., no nozzle changers yet,
empty-tape duct, etc.).
During the course of the upgrading process, details of the possible options will be described and/
or you will be referred to the pertinent separate manuals.
A downgrade is technically possible, however in this case the original machine data will have to
be saved. 2
2.2 Information Prior to Upgrading
2.2.1 Documentation Required in Addition to This Manual
All documentation required --> see: Section 2.7
2.2.2 Initial State of S-23 HM to be Clarified with Customer
Line computer UNIX:
Do the minimum requirements for installation of the LRU V 502.01 exist?
-> Requirements: see Software Version Description LRU V 502.01.
S-23 machines up to serial no. 350 inclusive are still equipped with a 14" monitor mounted on
a PC carrier 3 with a functional status of 01 or 02. Since a 15" monitor is always required for
upgrading to software version 502.xx, you will have to take a 15" e156 Touch Screen Monitor
and an e156 adapter including the mounting components (see Section 2.5.5 for the article
number) when carrying out this upgrade.
Fitting the e156 adapter modifies the PC carrier 3 with functional status 01 or 02 to allow the
15" monitor to be fitted as described in Section 2.8.6.
If the S-23 machine to be upgraded already has a 15" MCM15P1 monitor (article no.
00350896-01) installed (machines with serial nos. as of 351), this monitor remains fitted. In
2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option) SIPLACE S-23 HM
2.2 Information Prior to Upgrading 07/01 Issue
68
this event, the new 15" Touch Screen E156 monitor is only installed as an option or as dictated
by servicing requirements. In this case, the existing MCM 15 P1 adapter on the PC carrier 3 is
replaced by the e156 adapter (for article no. see Section 2.5.5).
Installing the option MTC during the course of the upgrading:
The opening for the MTC does NOT exist in machine frames up to series no. 449. In this case
you will also require the "Component reject box, component table" -> see: instructions for ret-
rofitting MTC on the S-25 HM.
If RV12-DLM1 heads are installed on the machine to be upgraded and their vacuum genera-
tors are still seated on metal brackets (instead of rubber-metal vibration buffers), these buffers
must also be installed here during the course of the upgrading.
Required:
In addition, one enclosure (DLM1_S23, Item no. 003455365-03 per 12-segment head) from
the retrofit kit of the RV6-DLM1 head (see: Section 2.5).
2.2.3 Determining the Total Time Expended incl. Options (Approximate Values)
Upgrading on customers premises, including installation of options:
Approx. 5 hours to install hardware EXCLUDING options and software upgrade V 502.xx at the
station.
Approx. 1 each for software upgrade V 502.xx at the station computer and line computer
Installation of options during the course of upgrading:
Approx. 1 hr. per RV6-DLM1 head with nozzle changer RV6 Standard for mech. installation
Approx. 5 hr. per RV6 head and nozzle changer RV6 Standard for
adjusting dynamics, calibrating head, component camera and nozzle changer, RV map-
ping, precision calibration
Approx. 4.5 hr. per MTC (see: retrofitting instructions for MTC), complete
Approx. 4.5 hr. total for "Head PCB, modular" and "PCB camera Multicolor" at both
gantries, including calibration of heads and cameras
see: retrofitting instructions for "PCB camera Multicolor")
2.2.4 Scope of Upgrade, Installation of the Following Components
Conveyor control TSP 210, backplane and I/O boards
Relay for automatic shutoff of compressed air
15" touch-screen monitor with monitor carrier (only if customer still has a monitor with a 14"
screen)
Nozzle changer bar with the two fiducials for position recognition
SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.2 Information Prior to Upgrading
69
Software version V 502.01 at station computer and line computer
NOTE:
The option MTC is possible following upgrading (see: "Options ..." below). 2
2.2.5 Options Possible after Upgrading
6-segment revolver head, modular (RV6-DLM1), at one or both gantries.
If there is only one 6-segment head, modular, the preferred location for installation is
gantry 1.
-> see: conversion instructions, Item no. 00191684-03 (G + E) and Section 2.8.7.
Nozzle changer for the 6-segment revolver head, modular (Section 2.8.8).
MTC
-> see: retrofitting instructions, Item no. 00192792-03 (G + E)
Head board, modular
-> see: retrofitting instructions, Item no. 00192919-01 (G + E) (in progress).
PCB camera Multicolor (requirement: modular head board).
-> see: retrofitting instructions, Item no. 00192232-01 (G + E)
NOTE:
The 6-segment revolver head is also named 6-nozzle head (on the user interface). 2