SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.8 Sequence: Modifying Hardware
83
Å Fasten the backplane with the 8 screws M2.5 from the retrofit kit:
To do so, use 4 screws M2.5 x 10 screws for the top row and 4 screws M2.5 x 8 for the bottom
row.
Å If you unplugged the connector from X99, plug it back in.
Å Plug the connector for the Interrupt TSP-210 machine controller (from the retrofit kit) on the
SMP backplane: To do so, plug the connector cable on the back of SMP board, slot 9, and
board slot 11 onto the plug connectors as shown in Fig. 2.8.4.
Å Re-install the cover 007 (see Fig. 2.8.2).
Å Make certain that none of the cables are pinched or are under tension:
Install the control unit and fasten it with the screw M5.
Fig. 2.8.5 View of the Control Unit after Modification
Å Plug in the 3 new I/O boards KSP-P219-A32 (from the retrofit kit) onto the SMP board slot 8-
10 (see: Fig. 2.8.5).
KSP-P219 (se)
SMP board slot 8
TSP-210
SMP board slot 11
KSP-P219 (sg)
SMP board slot 10
KSP-P219 (sf)
SMP board slot 9

2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option) SIPLACE S-23 HM
2.8 Sequence: Modifying Hardware 07/01 Issue
84
Fig. 2.8.6 Setting the DIL Switches
Å ATTENTION: Set the new assembly TSP-210 on the quad DIL switches S1 to Single or
Dual Conveyor (Fig. 2.8.6):
– Switch 1 to OFF in case of single conveyor 1,
– Set to ON in case of dual conveyor.
Å Install the assembly TSP-210 on SMP board slot 11: Fig. 2.8.5.
Å Plug the 12 connectors X2se – X5se (board at board slot 8), X2sf – X5sf (board at board slot
9), X2sg – X5sg (board at board slot 10) onto the I/O boards.
Å The firmware is not installed until all mechanical installation steps have been concluded, pref-
erably BEFORE installing the SW V 502.01 at the station (see: Section 2.9).
ON
1 2 3 4
12345678
ON
12345678
ON
S1
S2
S2
ON
1234
S1
ON
1234
Einfachtransport
Single Conveyor
Doppeltransport
Double Conveyor

SIPLACE S-23 HM 2 Retrofitting Instruct. S-23 HM to SW V 502.xx incl. RV6-DLM1 Head (Option)
07/01 Issue 2.8 Sequence: Modifying Hardware
85
2.8.4 Installing the Relay for Automatic Compressed Air Shutoff
2
Fig. 2.8.7 Terminal Panel LH side: Slot of Relay for Automatic Compressed Air Shutoff
Key:
1. Remove cable duct covers
2. Assembly A6
3. Assembly A2
4. Relay for automatic compressed air shutoff
Å Use the circuit drawing for installation and wiring (Fig. 2.8.8).
Å Remove the cable pit covers (see: Figure above).
Å Snap the relay from the retrofit kit onto the DIN rail. Position, see: Abb. top.
Å Wire the new cable W1, W2 and W3 from the retrofit kit: During the process, disconnect the
brown wire of the cable for the Jucomatik valve from A2 (+) and connect this cable to terminal
11 on the new relay.
1
4
2
3