presto_en.pdf - 第48页

Page 48 O p t i o n s M e n u Keyboard shortcut: Sh ift+F10 The Options menu hold s all the possible sett ings of the UP program. There is a g reat numb er of sett ing parameters. If you are not sure that all sett ings a…

100%1 / 101
Page 47
Erase code/main memory
A keyboard shortcut can be assigned in Options Key
shortcuts
This command erases the code/main memory. It cannot
be used if Code/Data Protection is active.
Erase data memory
A keyboard shortcut can be assigned in Options Key
shortcuts
This command erases the data memory and verifies it. It
cannot be used if Code/Data Protection is active.
Device Blank check
Keyboard shortcut: Shift+F9
This command opens a sub-menu with device erasure
verification options. Some of them may be not available
for certain device types.
Blank check all
Keyboard shortcut: F9
This command verifies whether the device is correctly
and completely erased.
Blank check all except data memory
A keyboard shortcut can be assigned in Options Key
shortcuts
This command verifies whether the device except the
data memory has been correctly erased.
Blank check of code/main memory
A keyboard shortcut can be assigned in Options Key
shortcuts
This command verifies whether the code/main memory is
correctly erased.
Blank check of data memory
A keyboard shortcut can be assigned in Options Key
shortcuts
This command verifies whether the data memory is
correctly erased.
Blank check of configuration memory
A keyboard shortcut can be assigned in Options Key
shortcuts
This command verifies whether the configuration memory
and ID positions (if device contains them) are correctly
erased.
Device Select device
Keyboard shortcut: F4
This dialog allows you to select a device type to be
programmed. Some memory types need to have their
data organization selected after the device type
selection.
Only devices supported by the currently selected
programmer are displayed in the dialog window. If you
want to select a device not supported by the current
programmer, select a different programmer type first.
For further information on selecting a device see
Device
Type Selection
.
Device Device info
Shows a window with information about connecting the
selected device to the programmer.
Page 48
Options Menu
Keyboard shortcut: Shift+F10
The Options menu holds all the possible settings of the
UP program. There is a great number of setting
parameters. If you are not sure that all settings are
correct, you may use the Load defaults button, which
returns all the settings to the initial (factory) state.
Advice
Program settings Load defaults button renews the state of
all settings on all tabs, i.e. even the color settings, for example.
Options Program settings
Programming
Keyboard shortcut: Shift+F10
This tab provides for setting all the general programming
parameters.
Settings concerning the programmer and the
communication port are described in
Programmer
Selection
.
A special
Device Select device window is available for
setting the device type.
Reload file before every programming
The program reads the current file with programming
data from the disc before each and every request to
program a device if this option is checked.
If the use of serial numbers is also activated requesting
reading the current file prior to programming, then the
file is read first and only then is the current serial number
written.
Keep manually modified data
When this choice is active, the file load before
programming does not rewrite manually changed data.
This choice affects only behavior of the file reload before
programming.
Warn before file load, when data in
some editor have been changed
When before load of the file before programming it is
found that data in some editor have been changed, the
program shows a warning.
Warn, when the loaded file has not
changed
Program shows a warning, when the content of the
loaded file has not changed from the previous
programming.
Program file locations only
The programming changes only the positions contained in
the file. First it reads the programmed device content,
then it reads the file content which replaces the data read
from the device. The addresses which are not contained
in the file hold the value read from the device. Finally the
memory is programmed.
Ask before erasing
With this option checked, the program asks for user
confirmation before erasing a device.
Ask before programming of OTP / Flash
/ Code/Data Protection / differential
A set of options determining which user confirmation
dialogs will or will not be displayed by the program.
The program asks just once except the Code/Data
Protection programming. If the program needs to ask
the user for additional information before actual
programming (such as Device has Code or Data
Protection. Do you want to erase it entirely?), it
Page 49
does not ask for further programming confirmation after
answering the first dialog.
Display fuse warning messages
The user can choose if warning messages should be
displayed for some fuses. It is recommended to leave this
option on.
Except for programming: Close status
window
This option closes the status window if no error occurs
during erasing, blank check, programming verification
and reading.
After programming: Close status
window
This option closes the status window if no error occurs
during programming and the subsequent verification.
Beep after successful finishing
With this option active, the program calls up the standard
Windows system beep if the operation (such as erasing,
programming, etc.) went smoothly.
Beep after unsuccessful finishing
With this option active, the program calls up the standard
Windows system beep if an error or warning occurs during
the operation (such as erasing, programming, etc.).
Turn off all sound for UP
With this option on, the program does not produce any
sounds.
Delay for VDD switching on/off when
supplied from programmer
This option is important for programming PCB-placed
devices via an ICSP cable. It determines the length of the
delay after voltage is connected to or disconnected from
a device.
Both PRESTO and FORTE feature an overcurrent
protection. This means that a test for excessive current of
approximately 100 mA in power supply voltage is
performed after connecting power to the device and
expiration of the delay time set in Switch on.
Similarly the delay time set in Discharge specifies how
late after switching the power supply off a check should
be performed if no voltage is present any longer at the
pin.
If a blocking capacitor is connected to the device's power
supply pins (recommended), the voltage at the pin
changes more slowly. This could cause problems during
programming, but they can be eliminated by prolonging
the charging and discharging time.
Too long a time increases the risk of damaging the device
if connected incorrectly while too short a time could
cause programmer's circuits to still detect excessive
current flowing to the application's capacitors. A formula
for an approximate determination of the necessary time
can be found in
Appendix B: Use of ICSP.
Do not perform Device ID check before
programming
This option switches off the Device ID check before
programming.
Do not perform blank check before cfg
word programming
Most rewritable devices can overwrite the configuration
word without erasing the whole device content. Skipping
the blank check of the configuration word utilizes this
possibility, i.e. the program ignores the not erased word.
This option does not apply to the whole-device
programming in which the device is erased completely. It
concerns only the configuration word and its overwriting.