2-1 2 Daily maintenance items Before beginning work In most cases, maintenance should be perfor med with the main power turned off. However , some maintenance tasks are per formed under emergency stop conditions with the…

2-1
2
Daily maintenance items
Before beginning work
In most cases, maintenance should be performed with the main power turned off.
However, some maintenance tasks are performed under emergency stop conditions with the power turned on.
In such cases, ensure adequate safety and press the emergency stop before beginning the maintenance.
The power is turned on during maintenance where any servo-axis must be operated or machine operation
checked. In this case, also ensure adequate safety before beginning the maintenance.
When operating the machine, make sure the following conditions are met.
n
Operating conditions
1. Supply air pressure is kept at correct pressure.
2. All safety covers are closed.
3. All feeder exchange carriages are securely clamped when they are used with the machine. (YS12 only)
4. Nozzles and other units are attached in place.

2-2
2
Daily maintenance items
1. Checking the nozzle
Solder sticking to the nozzle tip or a clogged nozzle hole can cause component pickup errors and
recognition errors. Poor nozzle spring action can also cause pickup and mounting errors. To prevent such
problems periodically inspect and clean each nozzle.
1.1 Check with software
n
How to check for a dirty nozzle (with the [Check Nozzle] button)
The term "dirty nozzle" as used here indicates shiny material such as solder adhering to the nozzle tip. This
shiny portion might be mistaken for a component and cause recognition errors. To check for this problem,
press the [Check Nozzles] button on the [Setup] screen while the nozzle tip picks up no components. The
camera finds the extent of grime or dirt on the nozzle tip.
e
1
Move the head.
Press the emergency stop button and move
the head so the nozzle is at a position where
it can be easily replaced.
2
Press the [Check Nozzles] button as
follows.
1. Cancel emergency stop.
2. Open the [Setup] screen and press the
[CheckNozzles]buttonin"Utilities".
54201-L5-00
3
Select the item to be executed.
After checking the displayed message,
select the desired button.
n
When [Yes] was selected
Performs auto nozzle change and checks all nozzles
that can be changed.
n
When [No] was selected
e
1. Press the emergency stop button and then move the
head to a position where a nozzle can be easily
changed.
2. Change the nozzle and press the [OK] button by
following the message.
3. Nozzle check begins after pressing the last [OK]
button.
54202-L5-00
4
Check the message.
Clean the nozzle if the check shows it is dirty.
54203-L5-00
n
NOTE
The "Check Nozzles" function is usually set for "Type 302A
nozzles" before shipment.
Selecting the item to be executed
Step 3
When [No] was selected
Checking the message
Step 4
Pressing the [Check Nozzles] button
Step 2
[Check Nozzles] button