00193922-01.pdf - 第199页
User Manual SIPLAC E HF Series 4 Setting up and commissioning Software Version SR.505.xx 05/2004 US Edition 4. 5 Setting up the placement machine 199 4.5.14.3 Aligning the plac ement machine with respect to the line Æ Po…

4 Setting up and commissioning User Manual SIPLACE HF Series
4.5 Setting up the placement machine Software Version SR.505.xx 05/2004 US Edition
198
Æ Make sure that the forks are evenly loaded when you lift the machine. A firm support between
the forks and placement machine will prevent the machine tilting when it is raised. This will also
prevent a one-sided load on the machine feet, which would deform the fixing of the machine
feet. We recommend that a second person watch the machine as it is raised, and make sure
that the machine does not tip to one side when lifted with the fork-lift.
4.5.14.2 Points that MUST be noted when transporting the machine
WARNING
When you are transporting the machine, make sure that
all
the feet are clear of the floor. If they
are not clear, the feet will drag along the floor or bump into obstacles. This could damage the
machine foot fixing in the machine frame.

User Manual SIPLACE HF Series 4 Setting up and commissioning
Software Version SR.505.xx 05/2004 US Edition 4.5 Setting up the placement machine
199
4.5.14.3 Aligning the placement machine with respect to the line
Æ Position the placement machine on the free location on the line using the fork-lift.
WARNING 4
Lower the placement machine slowly. A second person should look underneath to ensure
that all the machine foot touch the floor at the same time. If the machine feet on one side hit
the ground hard, the fixings may be damaged.
4
4.5.14.4 Aligning the placement machine with the air cushion transport system
Æ Place the four air cushions of the air cushion transport system beneath the machine frame.
Æ Raise the placement machine and align it with respect to the line.
Æ Check the distance from the PCB conveyor system of the adjacent machine. It should be be-
tween 1 mm and 3 mm.
Æ Lower the placement machine.
4
Fig. 4.5 - 20 Contact positions for the air cushion transport system
(1) Contact surfaces for the air cushion transport system

4 Setting up and commissioning User Manual SIPLACE HF Series
4.5 Setting up the placement machine Software Version SR.505.xx 05/2004 US Edition
200
4.5.15 Making final adjustments to the placement machine
Æ Place the machine's spirit level on the panels of the PCB conveyor in placement area 1 in both
the X and the Y directions (see Fig. 4.5 - 21
). The PCB conveyor width is set to 136 mm by
default.
PLEASE NOTE: 4
On the dual conveyor, place the spirit level only on the outer panels of the machine for ad-
justing in the X direction.
Æ Measure the distance between the top edge of the PCB conveyor and the floor. This distance
should be 800 mm, 900 mm, 930 mm or 950 mm.
4
Fig. 4.5 - 21 Adjusting the placement machine in the X and Y directions
4
4
Æ Use the size open-ended spanner to adjust the hexagon head screw M24x80 (item 1 in Fig.
4.5 - 22
) so that the label on the machine spirit level does not deviate from the zero point for
the requested PCB transport height.