00193922-01.pdf - 第69页

User Manual SIPLAC E HF Series 2 Operational safety Software Vers ion SR.505.xx 05/2004 US Edition 2.7 Residual voltages and discharge t imes in the ma chine 69 2.7 Residual v olt ages and dischar ge times in the machine…

100%1 / 358
2 Operational safety User Manual SIPLACE HF Series
2.6 Safety equipment Software Version SR.505.xx 05/2004 US Edition
68
2.6.6 Hand guard at the component trolley locations
WARNING 2
All locations must be equipped with feeders in order to guarantee operational reliability.
If there are not enough feeders available, unassigned locations should be fitted with a hand
guard (dummy feeder). When a waffle-pack tray (manual tray) is set up, the remaining locations
should again be protected with a hand guard.
Fig. 2.6 - 10 Hand guard for component trolleys
2
(1) Hand guard for 1 location item no. 00116961-01
(2) Hand guard for 6 to 10 locations item no. 00116962-01
(3) Hand guard for 11 to 20 locations item no. 00116963-01
User Manual SIPLACE HF Series 2 Operational safety
Software Version SR.505.xx 05/2004 US Edition 2.7 Residual voltages and discharge times in the machine
69
2.7 Residual voltages and discharge times in the
machine
If the emergency stop button is pressed or the placement system is switched off, the 250 VDC link
voltage for the gantry axes and the 145 VDC link voltage for the star axes are reduced to harmless
residual voltages in a very short time.
WARNING 2
The placement system is supplied with 3 x 208 VAC, 3 x 230 VAC, 3 x 380 VAC, 3 x 400 VAC or
3 x 415 VAC ± 5 %, 50/60 Hz mains voltage. This means that some parts of the system carry
potentially lethal voltages - even when switched off at the main power switch. Incorrect handling
of the placement system can therefore result in death or severe injury or considerable damage to
equipment.
Æ Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1).
Æ The guards over the power supply unit and the axis unit must ONLY be opened by appropri-
ately qualified and trained personnel.
Fig. 2.7 - 1 Power supply unit
2
(1)Padlock with bolt in the cover
(2)Main power switch
(3)Power supply unit behind the cover
(4)Axis unit
2 Operational safety User Manual SIPLACE HF Series
2.7 Residual voltages and discharge times in the machine Software Version SR.505.xx 05/2004 US Edition
70
Fig. 2.7 - 2 Measuring points on the power supply unit
2.7.1 Operating voltages, residual voltages and discharge times after pressing
the emergency stop button
2
Pins X11 and X13_1
measured to X12 (GND)
Voltage in normal
mode
Residual voltage after
emerg. stop Discharge times
X11 + 250 VDC < 10 VDC 7 sec
X13_1 + 145 VDC < 10 VDC 50 sec
Pin X13_4
measured to pin X3_7 (-)
Voltage in normal
mode
Residual voltage after
emerg. stop Discharge times
X13_4 + 30 VDC + 30 VDC -