7 Station extensions User Manual SIPLACE HF Series 7.2 Component c amera for the TwinHead, FC came ra Software Version S R.505.xx 05/2004 US Edition 300 7.2.1.2 Position of the component vision ca meras f or the T winHea…

User Manual SIPLACE HF Series 7 Station extensions
Software Version SR.505.xx 05/2004 US Edition 7.2 Component camera for the TwinHead, FC camera
299
7.2 Component camera for the TwinHead, FC camera
7.2.1 Structure of the CO camera (stationary, P&P (type 20) 8 x 8), FC camera
7
Fig. 7.2 - 1 Component vision camera for the TwinHead (stationary, P&P, type 20, 8 x 8), FC camera
7.2.1.1 Technical data
7
(1)Camera housing with integral camera and
camera amplifier
(2) Glass plate - over the illumination and lens
levels
Component dimensions 0.6 x 0.3 mm² up to 8 x 8 mm² for single component measure-
ment
Range of components 0201 to SO, PLCC, QFP, sockets, plugs, BGA, special compo-
nents, bare dies, flip-chips, shields
Min. lead pitch 0.25 mm
Min. ball/bump diameter 0.08 mm
Field of vision 11 x 11 mm²
Method of illumination Front-lighting (6 levels, programable as required)

7 Station extensions User Manual SIPLACE HF Series
7.2 Component camera for the TwinHead, FC camera Software Version SR.505.xx 05/2004 US Edition
300
7.2.1.2 Position of the component vision cameras for the TwinHead on the HF placement
machine
7
Fig. 7.2 - 2 Position of the component vision cameras for the TwinHead on the HF placement machine
(1) Assembly position for the component vision camera (stationary, P&P (type 20) 8 x 8), location 1
(2) Assembly position for the component vision camera (stationary, P&P (type 22) 50 x 40), loca-
tion 1
(3) Assembly position for the component vision camera (stationary, P&P (type 20) 8 x 8), location 3
(4) Assembly position for the component vision camera (stationary, P&P (type 22) 50 x 40), loca-
tion 3

User Manual SIPLACE HF Series 7 Station extensions
Software Version SR.505.xx 05/2004 US Edition 7.2 Component camera for the TwinHead, FC camera
301
7.2.1.3 Position of the component vision cameras for the TwinHead on the HF/3 placement
machine
7
Fig. 7.2 - 3 Position of the component vision cameras for the TwinHead on the HF/3 placement machine
(1) Assembly position for the CO vision camera (stationary, P&P (type 22) 50 x 40), location 3
(2) Assembly position for the CO vision camera (stationary, P&P (type 20) 8 x 8), location 3
7.2.2 Safety instructions for the TwinHead component cameras
during a placement head change
WARNING 7
When the placement head is changed from the TwinHead to the Collect&Place head, the Twin-
Head's component vision cameras (stationary, P&P, type 22, 50 x 40, and type 20, 8 x 8) must be
removed, otherwise the Collect&Place head will collide with the camera housings.