7 Station extensions User Manual SIPLACE HF Series 7.1 Nozzle changer Software V ersion SR.505.xx 05/2004 US Edition 280 7.1.1.7 Changing the magazine Æ T o remove the magaz ine, push the sp ring hook ( item 1 in Fig. 7.…

User Manual SIPLACE HF Series 7 Station extensions
Software Version SR.505.xx 05/2004 US Edition 7.1 Nozzle changer
279
7.1.1.6 Notes on operation
Æ When you fill a magazine with a certain nozzle type for the first time, attach an adhesive label
to identify the type.
PLEASE NOTE 7
Fill the magazines off the machine and always replace complete magazines. 7
Æ Open the locking plate and place the nozzles in the nozzle holders.
Æ Close the locking plate so that the nozzles cannot drop out of the magazines.
CAUTION 7
Before you fill magazine, make sure that all the nozzles on the Collect&Place head have
been returned to their magazines. 7
Æ Programming the nozzle changer is described in the SIPLACE Pro user manual.
PLEASE NOTE 7
Æ Do not allow components to drop onto the magazines. If they do, they could jam the locking
plate.
Æ Do not allow components to drop onto free feeder locations. They will stick to the magnetic bar.
Production may have to be interrupted if the feeders are not placed on the component table
correctly. You should therefore regularly clean the magazines and free locations.

7 Station extensions User Manual SIPLACE HF Series
7.1 Nozzle changer Software Version SR.505.xx 05/2004 US Edition
280
7.1.1.7 Changing the magazine
Æ To remove the magazine, push the spring hook (item 1 in Fig. 7.1 - 6) away from the maga-
zine. Lift the magazine out of the carrier.
7
Fig. 7.1 - 6 Changing the magazine
(1) Spring hook
(2) Retaining clamp
(3) Centering hole
(4) Slot
(A) Push the spring hook away from the magazine

User Manual SIPLACE HF Series 7 Station extensions
Software Version SR.505.xx 05/2004 US Edition 7.1 Nozzle changer
281
PLEASE NOTE
Make sure that you insert the magazine so that the centering pins slide into the centering hole
(item 3) and slot (item 4). 7
Æ First place the side of the magazine with the numbered nozzles 1, 2, 3 and 4 on the base. The
retaining clamp (item 2) must slide into the slot in the magazine.
Æ Push the spring hook away from the magazine.
Æ Press the magazine so that it lies flat on the base, then release the spring hook. The spring
hook must latch into place.
7.1.1.8 Position detection
Every magazine of the nozzle changer has a positioning fiducial for position detection.
7
Fig. 7.1 - 7 Nozzle changer - position detection
(1) Positioning fiducial
(2) Position of the nozzles in the magazine with respect to the positioning fiducial