PPS Pro version 8.2.pdf - 第170页

User Manual 4022 591 98247 166 PPS-Pro v8.2 05.07 Guidelines for using PPS-Pro third 3. This inf ormation is used when part s have to be pla ced last, these are transferr ed to the ma chine with the high e st LogicalP os…

100%1 / 194
4022 591 98247 User Manual
05.07 PPS-Pro v8.2 165
Guidelines for using PPS-Pro
For the FCM-IIM and FCM-IIXM and additional set of parameters can be
changed by the user:
TABLE 31 ALE Settings Attributes for FCM-IIM & FCM-IIXM
NOTE: When DEFAULT is defined, the optimizer calculates the Reference Points. The
user can overrule this by defining these coordinates himself.
A.6.3.4 AX machine Production Parameters
For the AX base3 and base5 machines, following important parameters are
user definable:
TABLE 32 ALE Settings Attributes for AX
The LogicalPositionInLine defines the place of the machine in the line. Thus, if
an SMD line exists of AX machine – AX machine – AQ-1 machine, then the
logical position of the first AX machine is 1, of the second one is 2 and for the
Parameter FCM-IIM - FCM-IIXM
RightReferencePin DEFAULT or <value> e.g.: 123.45
LeftReferencePin DEFAULT or <value> e.g.: -34.29
BadMarkGrouping ON or OFF
FiducialGrouping ON or OFF
Parameter AX
BaseType BASE_3 or BASE_5
ProductionMode LOCAL or DISTRIBUTED
PanelFidMark
BoardFidMark
PartFidMark
<user definable> identifi-
ers for Panel, Circuit and
Part fiducials
BadMarkId <user definable>
LogicalPositionInLine 1 or 2 or 3 etc.
ProcessDataVersion 1.0
ControlSoftwareVersion 1.0
DoNotDuplicatePreassignment TRUE or FALSE
AlignmentMatrixPerCircuit TRUE or FALSE
MaxNoFiducialsPerAlignment-
Matrix
2 or 3
BadMarksRequireFiducials TRUE or FALSE
EnableNeighborhoodRestric-
tions
TRUE or FALSE
ProductionDirection RIGHT_TO_LEFT or
LEFT_TO_RIGHT
User Manual 4022 591 98247
166 PPS-Pro v8.2 05.07
Guidelines for using PPS-Pro
third 3. This information is used when parts have to be placed last, these are
transferred to the machine with the highest LogicalPositionInLine.
PanelFidMark, BoardFidMark, PartFidMark fields: When the used fiducials,
either in LAR- or DSF ProductionMode have no name assigned, then this user
definable name will be used in the Placement Program. This name refers to
the used shape definition file (vision file) on the AX machines.
BadMarkId field: Specifies the name that has been assigned in the MDF file
(CAD) file for the badmark.
The DoNotDuplicatePreassignments field: When preassigned parts are not
allowed to be duplicated this option can be used. Note that parts in the PCB
should be reachable (and the fiducials should be read in advance), otherwise
this option should be turned off.
The AlignmentMatrixPerCircuit field: Only the fiducials in the circuit itself may
be used for alignment of the parts in the circuit. (Important when carriers are
used.)
The MaximumNoFiducialsPerAlignmentMatrix field: This field defines the
number of fiducials that will be scanned per Alignment Matrix.
The BadmarksRequireFiducials field: This field specifies if it is mandatory to
first read fiducials before badmarks can be read, or not. (Practical situation is
circuit carriers without fiducials.)
The EnableNeighborhoodRestrictions field: This field specifies if the optimizer
for AX machines has to take care that the placement of smaller parts next to
larger parts can cause the nozzle shaft to displace the larger parts. By turning
on this function the optimizer will generate programs where the larger parts
will be placed after the small parts that are nearby have been placed.
The ProductionDirection field: Can only be used if special hardware modifi-
cations have been done on the machine in order to allow PCB transport in
reverse direction.
NOTE: See for the other parameters the ALE Description.
A.6.3.5 ACM, AQ-1 and D9 Production Parameters
For these machines the following parameters can be set:
Parameter ACM – AQ-1, AQ-2 – D9
ModulePosition1 FLUX or TEU
ModulePosition2 CSP, FP (AQ1)
or
DV_SFOV, DV_LFOV (AQ2)
4022 591 98247 User Manual
05.07 PPS-Pro v8.2 167
Guidelines for using PPS-Pro
TABLE 33 ALE Settings Attributes for ACM, AQ-1, D-9
The Mark parameters refer to the used shape definition file (vision file) on
these machines.
NOTE: When a module position is not defined by the user then it is not used.
(Affects PlaceLast functionality)
ModulePosition3 CSP, FP (AQ1)
or
DV_SFOV, DV_LFOV (AQ2)
ModulePosition4 COPLANARITY or TEU
ModulePosition5 FLUX
PanelFidMark User definable vision filename on machine, e.g.: CIRCLE
BoardFidMark User definable vision filename on machine, e.g.: CIRCLE
PartFidMark User definable vision filename on machine, e.g.: CIRCLE
PanelBadMark User definable vision filename on machine, e.g.: SQUARE
BoardBadMark User definable vision filename on machine, e.g.: SQUARE