00191297-02.pdf - 第236页
6 Vision functions User Manual S-23 HM 6.6 Test Component Software Version SR.405.xx 05/ 99 Issue 234 6 Fig. 6.6 - 8 ’T es t component’ flow chart, LEAD, GRI D, and BALL meas. modes ’Test component’ menu options ’LEAD’, …

User Manual S-23 HM 6 Vision functions
Software Version SR.405.xx 05/99 Issue 6.6 Test Component
233
6
Fig. 6.6 - 7 ’Test component’ flow chart, ROW and CORNER measure mode menus’
’Test component’ menu options
’ROW measure mode’ and ’CORNER measure mode’ menus
’ROW measure mode’ menu
’CORNER measure mode’ menu
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Measurement
No. of pins to be measured
at each corner
One window
across the whole
lead window
No. of pins
at each corner
Cancel Accept
Angle measurement
activated
Yes/No
low
medium
high
very high
Resolution in
meas. direction
Resolution in
direction of
integration
low
medium
high
very high
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Measurement
Use package
form edges
For the
rotational
windows
For the
translational
windows
Cancel Accept
Cancel Accept
’ROW measure mode’ menu -
integration settings

6 Vision functions User Manual S-23 HM
6.6 Test Component Software Version SR.405.xx 05/99 Issue
234
6
Fig. 6.6 - 8 ’Test component’ flow chart, LEAD, GRID, and BALL meas. modes
’Test component’ menu options
’LEAD’, ’GRID’, and ’BALL’ measure mode menus
’LEAD measure mode’ menu ’
Tip measurement
via inner tips
Center
measurement
Tip measurement
via outer tips
Measurement Window
Separately
for each pin
Combined
windows
Cancel Accept
Number of
balls to be
measured
Cancel Accept
Fast
Robust
Measurement Evaluation
Position
and
existance
Quality
Cancel Accept
’GRID measure mode’ menu ’BALL measure mode’ menu

User Manual S-23 HM 6 Vision functions
Software Version SR.405.xx 05/99 Issue 6.6 Test Component
235
6.6.3 Select Package Form Menu
If you select the Test component option in the Main view menu, the following actions will occur: 6
– The functions for the vision system are activated in the station computer
– The Select package form menu will drop down.
– The station computer will determine the package form numbers list with commentaries from
the set-up.
Fig. 6.6 - 9 Select package form menu
The menu allows you to choose between the following options, as the diagram shows: 6
– Selection of the camera types (80F machines only).
– Load GF data
– Save GF data
NOTE 6
Buttons are active when the text on the button is black (rather than gray). This means that you can
launch the associated function by clicking on the button with the mouse.