00191297-02.pdf - 第29页

User Manual S-23 HM 1 Introduction Software Version SR.405.xx 05/99 Issue 1.8 Technical data - ratings 27 1.8 T echnical dat a - ratings 1.8.1 T echnical da t a - elect rical ratin gs 1.8.2 T echnical dat a - compressed …

100%1 / 422
1 Introduction User Manual S-23 HM
1.7 Connection data for the placement system Software Version SR.405.xx 05/99 Issue
26
DANGER
The placement system is supplied with 3 x 400 V or 3 x 208 V (US version) ± 10%, 50/60 Hz main
power voltage. This means that some parts of the system carry potentially lethal voltages - even
when switched off at the main switch. Incorrect handling of the placement system can therefore
result in death or severe injury or considerable damage to equipment. 1
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 1
User Manual S-23 HM 1 Introduction
Software Version SR.405.xx 05/99 Issue 1.8 Technical data - ratings
27
1.8 Technical data - ratings
1.8.1 Technical data - electrical ratings
1.8.2 Technical data - compressed air supply
1.8.3 Technical data - compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1) 1
1.8.4 Technical data - noise emissions
1.8.5 Technical data - admissible environmental influences
Supply voltage 3 x 400 VAC ± 10 %; 50/60 Hz (Europe)
3 x 208 VAC ± 10 %; 50/60 Hz (U.S.A)
Fuses 3 x 16 A (3 x 400 VAC)
3 x 32 A (3 x 208 VAC)
Total connected load 5 kVA
Total output 5 kW
Power failure Up to 10 msec
Compressed air pressure supply min. 5.5 bar, max. 10 bar
Compressed air consumption 400 Nl/min.
Operating pressure 5.2 bar (fixed)
Particle size 0.1 µm
Particle density 0.2 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Dew point under pressure (class 4) Dew point +3°
Emission value at a workstation (L
pAc
) 71 dB (A) DIN EN ISO 11204 (i)
Sound power level (L
WAc
) 85 dB (A) E-DIN EN ISO 3744 (i) 001-0307
Ambient temperature Between 15°C and 35°C
Atmospheric humidity 30 to 75%
(but no higher than 45% on average in order to prevent
any possibility of condensation on the machine.)
1 Introduction User Manual S-23 HM
1.9 Dimensions and weight of the placement system Software Version SR.405.xx 05/99 Issue
28
1.9 Dimensions and weight of the placement system
1.9.1 Dimensions of the placement system
1
Fig. 1.9 - 1 Dimensions of the placement system
1.9.2 Technical data - dimensions, weight
Length 1587 mm including conveyor belts
Width 2.455 mm including brackets
Height with warning lamp 1836 mm standard height
Ground clearance 120 mm standard height
Weight of basic module 1500 kg
Weight fully equipped approx. 2000 kg
Admissible load per unit area on foundation 1000 kg/m² min.
Load per unit area on mounting feet 4.42 kg/cm²