00191297-02.pdf - 第28页

1 Introduction User Manual S-23 HM 1.7 Connection data for the placement system Software Version SR.405.xx 05/99 Issue 26 DANG ER The placeme nt system is suppli ed with 3 x 400 V or 3 x 208 V (US ve rsion) ± 10%, 50/60 …

100%1 / 422
User Manual S-23 HM 1 Introduction
Software Version SR.405.xx 05/99 Issue 1.7 Connection data for the placement system
25
1.7 Connection data for the placement system
1.7.1 Electrical and pneumatic connection points on the placement system
1
Fig. 1.7 - 1 Electrical and pneumatic connection points on the placement system
(1) Compressed air unit
(2) Connection for compressed air line
(3) Main power filter Z1
(4) Hole for power cable
(5) Service socket
(6) Compressed air supply connection for component changeover table
(7) Power supply connection for component changeover table
(8) Communications connection for component changeover table
(9) LAN connection in the control unit
(10) Main power switch
1 Introduction User Manual S-23 HM
1.7 Connection data for the placement system Software Version SR.405.xx 05/99 Issue
26
DANGER
The placement system is supplied with 3 x 400 V or 3 x 208 V (US version) ± 10%, 50/60 Hz main
power voltage. This means that some parts of the system carry potentially lethal voltages - even
when switched off at the main switch. Incorrect handling of the placement system can therefore
result in death or severe injury or considerable damage to equipment. 1
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 1
User Manual S-23 HM 1 Introduction
Software Version SR.405.xx 05/99 Issue 1.8 Technical data - ratings
27
1.8 Technical data - ratings
1.8.1 Technical data - electrical ratings
1.8.2 Technical data - compressed air supply
1.8.3 Technical data - compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1) 1
1.8.4 Technical data - noise emissions
1.8.5 Technical data - admissible environmental influences
Supply voltage 3 x 400 VAC ± 10 %; 50/60 Hz (Europe)
3 x 208 VAC ± 10 %; 50/60 Hz (U.S.A)
Fuses 3 x 16 A (3 x 400 VAC)
3 x 32 A (3 x 208 VAC)
Total connected load 5 kVA
Total output 5 kW
Power failure Up to 10 msec
Compressed air pressure supply min. 5.5 bar, max. 10 bar
Compressed air consumption 400 Nl/min.
Operating pressure 5.2 bar (fixed)
Particle size 0.1 µm
Particle density 0.2 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Dew point under pressure (class 4) Dew point +3°
Emission value at a workstation (L
pAc
) 71 dB (A) DIN EN ISO 11204 (i)
Sound power level (L
WAc
) 85 dB (A) E-DIN EN ISO 3744 (i) 001-0307
Ambient temperature Between 15°C and 35°C
Atmospheric humidity 30 to 75%
(but no higher than 45% on average in order to prevent
any possibility of condensation on the machine.)