1 Introduction User Manual S-23 HM 1.10 Setting up the placement system Software Version SR.405.xx 05/99 Issue 30 1.10 Setting up the placeme nt system 1.10.1 T ransport dimensions 1 Fig. 1.10 - 1 Dimensions of the place…

100%1 / 422
User Manual S-23 HM 1 Introduction
Software Version SR.405.xx 05/99 Issue 1.9 Dimensions and weight of the placement system
29
1.9.3 The placement system’s center of gravity
1
Fig. 1.9 - 2 The placement system’s center of gravity
X coordinate 0 mm 1
Y coordinate -80 mm 1
Z coordinate 350 mm high 1
T PCB transport direction 1
1
These center of gravity coordinates relate to placement systems with a PCB transport height of
830 mm. 1
1 Introduction User Manual S-23 HM
1.10 Setting up the placement system Software Version SR.405.xx 05/99 Issue
30
1.10 Setting up the placement system
1.10.1 Transport dimensions
1
Fig. 1.10 - 1 Dimensions of the placement system during transportation and setting up
A Points for attaching the fork-lift truck (fork length 1600 mm) 1
(1) Length 1587 mm
(2) Width 1921 mm
(3) Height 1836 mm
(4) Input conveyor
(5) Output conveyor
1
The PCB conveyor height is 830 mm ± 15 mm. 1
User Manual S-23 HM 1 Introduction
Software Version SR.405.xx 05/99 Issue 1.10 Setting up the placement system
31
1.10.2 Transport configuration and transportation
The following components are not installed when the placement system is delivered from the fac-
tory: 1
keyboards
–monitors
fault indicator lamps and
component tables
È Install the dismantled components for commissioning.
È Use a fork-lift truck to transport the placement system with a minimum fork length of 1600 mm.
È Attach the fork-lift truck only at the indicated points.
1.10.3 Quality of the foundation
È Ensure that
you set up the placement system on a firm and non-vibrating foundation.
the load bearing capacity per unit area of the foundation is greater than 1000 kg/m².
1.10.4 Compressed air supply
The pressure of the compressed air supply must be 5.5 bar min (max. permissible value
10 bar).
The compressed air must conform to the above specification.
This can be achieved with 1
oil-free compressors, e.g. Atlas, Copco type ZR4
compressed air washer/driers
micro-filters, series X, e.g. from Zander
1.10.5 Power supply
The power socket must be fused with the following fuse ratings:
3 x 16 A for 3 x 400 VAC 1
3 x 32 A for 3 x 208 VAC 1