FX-3RA_SPE_EN.pdf - 第11页
- 7 - 4. SPECIFICA TIONS 4- 1. Basic specification s ① Basi c s peci fications FX - 3R A Board spec ificati ons L- PW B XL - PW B Board dimens i ons S tandard 410×360m m 610×560m m L- W ide ( Option ) 510×360m m - Longer…

- 6 -
Machine Style FX-3RAL FX-3RAXL
Equipment device
Feeder float sensor
○
○
Automatic tool change unit (ATC)
○
○
Flexible calibration system (FCS)
○
○
FCS adjustment jig
●
●
Feeder position indicator (FPI)
●*1 ●*1
SOT direction inspection table
●*1
●*1
Component verification (CVS)
●*1
●*1
Non-stop operation
-
-
Production support system
External programming unit (EPU)
● ●
Floor productivity improvement support system
Production support system.
・
IS
●
●
・
IS Lite
●
●
・
JaNets
●
●
production management system
・
IFS-NX
●
●
Flexline CAD
●
●
White list type anti-virus software
○
○
Feeder bank (Mechanical type)
Mechanical feeder bank (fixed type)
○
○
Mechanical feeder bank (Feeder exchange trolley type)
●*1 ●*1
Trolley for mechanical feeder
●*1
●*1
Intelli trolley(RFID) for mechanical feeder
●*5
●*5
Connector bracket
●*1
●*1
IC collection belt unit
●
●
Feeder setup stand ● ●
Trash box
●
●
Tape cutter
●
●
Component supply unit
●
●
- Tape feeder / Stick feeder / Bulk feeder
●*5
●*5
Feeder bank (Electric type)
Electric feeder bank (fixed type)
●*1
-
Electric feeder bank (Electric feeder exchange trolley type)
●*1
●*1
Trolley for electric feeder
●*1
●*1
Intelli trolley(RFID) for electric feeder
●*1 *5
●*1 *5
Tape cutter unit ●*1 ●*1
IC collection belt unit
●
●
Feeder setup stand for electric feeder
●
●
Power supply for electric bank
●
●
Component supply unit
●
●
- Tape feeder / Stick feeder
●*5 ●*5
*1 This option is a factory-set option.
*2 Applicable only to the L(large) PWB machine.
*3 Applicable only to the XL(extra large) PWB machine.
*4 When the L-wide PWB specification is adopted, pin reference cannot be selected.
*5 RFID compliance is necessary when you use production control system..
(For mountable models and models for which a countermeasure can be taken later, refer to
the production management system product specification.)
*6 This is not mounted on the machine when a placement monitor is selected.
*7 LNC 61 are heads exclusively designed for a placement monitor into which an ultra-miniature
camera is incorporated.
The specifications of recognition with laser are equivalent with those of LNC60.

- 7 -
4. SPECIFICATIONS
4-1. Basic specifications
① Basic specifications
FX-3RA
Board specifications
L-PWB
XL-PWB
Board
dimensi
ons
Standard
410×360mm
610×560mm
L-Wide
(
Option
)
510×360mm -
Longer sized
PWB in X
axis (Option)
800×360mm(L、L-wide)
800×560mm
Board transport
reference position
Front side or rear side Front side
Supported languages
English, Japanese, Chinese and Korean
Conveyor height
900/950±20mm (for Japan, China, Korea and South east Asian
countries) (Note1)
950±20mm (for Europe and the U.S.A.)
Component height
6mm specifications (SC)
Component size
0402 to 33.5mm
Component placement
speed
(
IPC9850
)
66,000(CPH) (Note2) 51,500(CPH) (Note2)
Placement accuracy
±50μm (Cpk
≧
1)
Number of component to
be placed
A maximum of 240 types(on a Electric Double Tape feeder)
EN Specifications
Enable
Note1 The board transport height of 950 ± 20 mm (for Japan, China, Republic of Korea, and
South East Asia) is an option.
Note 2 For the component placement speed when the placement monitor is used, refer to 4-3
Placement cycle time.
②Recognition devices and heads.
Recognition device
Description
Standard LNC60
The laser sensor LNC60 allows six nozzles to
pick up components at the same time and
recognize them on the fly at a time.
Option LNC61
This is a laser sensor equipped with a
subminiature camera for a Placement Monitor.

- 8 -
4-2. Mechanical/Electrical Specifications
4-2-1 Usage environment conditions
FX-3RA
Power supply
Voltage
Three-phase 200V, 220V, 240V, 380V, 400V, 415V AC ±10%
(see Note 1)
Frequency 50/60 Hz
Rated apparent
power
Maximum 8.5 kVA
Air supply
Air pressure 0.50 ± 0.05 MPa dry air
Maximum air
consumption
150 L/min (ANR) (see Note 2)
Environment
requirements
During
operation
Temperature
10°C to 35°C
Accuracy guaranteed
temperature
20°C to 25°C
Humidity 30 to 80% RH (No condensation)
Altitude 1,000m or less
Transportation
or storage
Temperature
-15°C to 70°C
Humidity 20% to 95%RH (No condensation)
Noise 75 dB (A) or less (see Note 3)
Installation conditions
(For EN machine)
Overvoltage category Category Ⅲ according to IEC60664-1
Pollution degree Degree 3 according to IEC60664-1
Note 1: Any power supply cable for the primary side is not supplied with the machine.
We make no warranties against any accident of the primary side wiring caused by
short-circuit of a power cable and so on. Be sure to select the appropriate breaker
and power cable at your own risk.
Use a 8-mm
2
or more diameter of a power cable for each phase at the primary side.
Note that the appropriate cross-section area of a power cable varies depending on
its class, facility condition, length and the supplied power voltage. Therefore, be
sure to use a power cable that conforms to the regulations of the installation site.
Applicable sectional areas of primary side power cable lengths
Supply power
Primary-side power cable length(m)
Less than 20m 30m 40m 50m
AC 200/220/240V
Applicable
sectional area
(mm
2
)
8 8 10 12
AC 380/400/415V 8 8 8 8
Note that a 3-phase 50 A breaker is attached on the power supply incoming section
of FX-3RA.
Peak current (when 200 V AC 3-phase power supply is used): 90 A
Note 2: About ANR: Temperature 20
°
C,Absolute pressure 0.1 MPa (= 100 kPa=1 bar) and
Relative humidity 65%
The necessary air supply shall be calculated as follows:
In case of 150 L/min (ANR), 150/0.926 = 162 L/min: 162 L/min or more air supply
is required.
Note 3: This value was measured with conforming to the JIS Z8731 regulation.