FX-3RA_SPE_EN.pdf - 第12页
- 8 - 4- 2. Mechanical/Electrical Speci fica tion s 4-2-1 Us age environment conditions FX - 3R A Power supply V oltage Three - phas e 200V , 220V , 240V , 380V , 400V , 415V AC ±10% (see Note 1) Frequency 50/60 Hz Rated…

- 7 -
4. SPECIFICATIONS
4-1. Basic specifications
① Basic specifications
FX-3RA
Board specifications
L-PWB
XL-PWB
Board
dimensi
ons
Standard
410×360mm
610×560mm
L-Wide
(
Option
)
510×360mm -
Longer sized
PWB in X
axis (Option)
800×360mm(L、L-wide)
800×560mm
Board transport
reference position
Front side or rear side Front side
Supported languages
English, Japanese, Chinese and Korean
Conveyor height
900/950±20mm (for Japan, China, Korea and South east Asian
countries) (Note1)
950±20mm (for Europe and the U.S.A.)
Component height
6mm specifications (SC)
Component size
0402 to 33.5mm
Component placement
speed
(
IPC9850
)
66,000(CPH) (Note2) 51,500(CPH) (Note2)
Placement accuracy
±50μm (Cpk
≧
1)
Number of component to
be placed
A maximum of 240 types(on a Electric Double Tape feeder)
EN Specifications
Enable
Note1 The board transport height of 950 ± 20 mm (for Japan, China, Republic of Korea, and
South East Asia) is an option.
Note 2 For the component placement speed when the placement monitor is used, refer to 4-3
Placement cycle time.
②Recognition devices and heads.
Recognition device
Description
Standard LNC60
The laser sensor LNC60 allows six nozzles to
pick up components at the same time and
recognize them on the fly at a time.
Option LNC61
This is a laser sensor equipped with a
subminiature camera for a Placement Monitor.

- 8 -
4-2. Mechanical/Electrical Specifications
4-2-1 Usage environment conditions
FX-3RA
Power supply
Voltage
Three-phase 200V, 220V, 240V, 380V, 400V, 415V AC ±10%
(see Note 1)
Frequency 50/60 Hz
Rated apparent
power
Maximum 8.5 kVA
Air supply
Air pressure 0.50 ± 0.05 MPa dry air
Maximum air
consumption
150 L/min (ANR) (see Note 2)
Environment
requirements
During
operation
Temperature
10°C to 35°C
Accuracy guaranteed
temperature
20°C to 25°C
Humidity 30 to 80% RH (No condensation)
Altitude 1,000m or less
Transportation
or storage
Temperature
-15°C to 70°C
Humidity 20% to 95%RH (No condensation)
Noise 75 dB (A) or less (see Note 3)
Installation conditions
(For EN machine)
Overvoltage category Category Ⅲ according to IEC60664-1
Pollution degree Degree 3 according to IEC60664-1
Note 1: Any power supply cable for the primary side is not supplied with the machine.
We make no warranties against any accident of the primary side wiring caused by
short-circuit of a power cable and so on. Be sure to select the appropriate breaker
and power cable at your own risk.
Use a 8-mm
2
or more diameter of a power cable for each phase at the primary side.
Note that the appropriate cross-section area of a power cable varies depending on
its class, facility condition, length and the supplied power voltage. Therefore, be
sure to use a power cable that conforms to the regulations of the installation site.
Applicable sectional areas of primary side power cable lengths
Supply power
Primary-side power cable length(m)
Less than 20m 30m 40m 50m
AC 200/220/240V
Applicable
sectional area
(mm
2
)
8 8 10 12
AC 380/400/415V 8 8 8 8
Note that a 3-phase 50 A breaker is attached on the power supply incoming section
of FX-3RA.
Peak current (when 200 V AC 3-phase power supply is used): 90 A
Note 2: About ANR: Temperature 20
°
C,Absolute pressure 0.1 MPa (= 100 kPa=1 bar) and
Relative humidity 65%
The necessary air supply shall be calculated as follows:
In case of 150 L/min (ANR), 150/0.926 = 162 L/min: 162 L/min or more air supply
is required.
Note 3: This value was measured with conforming to the JIS Z8731 regulation.

- 9 -
4-2-2 Outside dimension (except for the largest projections)
L-PWB, L-Wide-PWB specification (Unit: mm)
2020/2070
1650 (L,L-Wid e )
2420(L,L-Wid e )
2650(L) , 28 80 ( L-Wi de )
基板搬送高さ
900/950
1530/1580
1995/2045
XL-PWB specification
2020/2070
1850
2430
2880
基板搬送高さ
900/950
1530/1580
1995/2045
4-2-3 Mass
L-PWB、L-Wide-PWB specification: 3,500kg
XL-PWB specification: 3,750kg
4-3. Component placement Cycle Time (A number of components to
be placed per an hour)
L-PWB、L-Wide-PWB specification: 66,000 CPH (IPC9850)
XL-PWB specification: 51,500 CPH (IPC9850)
*1: This is a number of components to be placed for one hour when 400 1608, 1005 or
0603 components are placed onto 200 mm × 200 mm board at an angle of 0, 90, 180
and 270 degrees sequentially.
*2: The mounter places a 0402 component sequentially, and the cycle time is 51,500CPH
(for L, L-wide PWB) and 40,500CPH (for XL PWB).
*3: When you use the 0402 component support function to place a 0402 component on a
board, the mounter does not pick up two or more 0402 components simultaneously.
However, it can pick up a 0402 component(s) and other type component(s)
simultaneously if the other head is located within the simultaneous pick-up area viewed
from the placement head for a 0402 component.
*4: When the placement monitor is used, the placement cycle time of 3% max. becomes
slower. When the “The system pauses if a component existence error occurs” is used
in the placement monitor setting, the placement cycle time of 40% max. becomes
slower.
Conveyor height
Conveyor height
(90)
(90)